INSTALLATION
NOTICE:Ifyourinstallationdoes not meet the minimum clearances shown, you must do one of the following:
•raise the mantel to an accept- able height
•remove the mantel
1.Frame in rough opening. The firebox fram- ing should be constructed of 2 x 4 lumber or heavier. Use dimensions in Table 1 and rough opening layout in Figure 7a. Adjust framing so that firebox flushes with finished wall surface. If installing in a corner, use dimensions in Figures 7b, 7c and 7d for rough opening.
2.Install gas piping to firebox location. See In- stalling Gas Line, page 12 and Connecting to Gas Supply in log set owner’s manual.
Table 1
Rough Opening Dimensions for
Front Width |
| Depth |
Model (Inside to Inside) | Height | (Min.) |
32" |
| 34 7/8" | 36 3/4" | 16 1/4" |
36" |
| 41 1/2" | 40 1/2" | 20 3/4" |
42" |
| 48 5/8" | 44 1/2" | 22 5/8" |
Figure |
| Depth |
|
|
7a |
|
|
| |
| (Minimum) |
| ||
|
| Height |
|
|
|
| Width |
| |
|
| (InsidetoInside) |
| |
FOR 32" MODELS | 0" CLEARANCE | |||
Figure |
|
|
|
|
7b |
| 39 3/8" |
| 27 3/4" |
|
|
|
| |
*10 1/2" | 34 1/2" |
| *10 1/2" | |
|
| 55 5/8" |
|
|
FOR 36" MODELS |
|
| ||
Figure |
|
| 0" CLEARANCE | |
|
|
|
| |
7c | 50 3/8" |
|
| |
|
|
|
| 35 5/8" |
Wall board or facing material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projections off of the facing material.
Framing
Material
Firebox
Screen
|
| Mantel Shelf | |||||
|
| Note: Any portion of the | |||||
|
| mantel shelf must NOT | |||||
12" | extend beyond this profile. | ||||||
|
|
|
|
| |||
6 3/4" |
|
|
|
| |||
|
|
|
| ||||
1 1/2" |
|
|
|
| |||
|
|
|
| ||||
|
| Noncombustible |
|
|
| ||
|
| Material May | 12" | 16" | 20" | ||
|
| Project Off this | |||||
|
| Surface above |
|
|
| ||
|
| the Firebox Hood |
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
| Note: All vertical | ||||
Supplied | measurements are | ||||||
from top of fireplace | |||||||
Firebox Hood | |||||||
hood opening to |
Must Be Used bottom of mantel shelf. | |
at All Times | These minimum |
| clearances replace any |
| other recommended |
| clearances supplied |
| with your ANSI Z21.11.2 |
| approved gas logs. |
|
| 41 1/2" | *14 1/2" |
|
| 71 1/4" |
|
FOR 42" MODELS |
| 0" CLEARANCE | |
Figure |
| ||
|
| ||
7d | 58" |
|
|
|
|
| |
|
|
| 41" |
| *17" | 48" | *17" |
|
| 82" |
|
*These dimensions allow for min. Clearances to a 45° projected side wall. However, clearances to projected mantel trims and facings are allowed within a min. Of 16" to a perpenducular wall as shown in figure 5, on page 10.
Figure 6 - Minimum Mantel Clearances
for
www.fmiproducts.com | 11 |