Operating Fireplace

Millivolt models

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup- plier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, column 1.

2.Turn wall switch to the OFF position.

3.Turn off all electric power to the appliance.

4.Open control access panel.

5.Push in gas control knob and turn clock-

wise to the OFF position (see Figure 23). Note: It is recommended that you maintain the gas control knob in the full OFF position during lengthy periods of seasonal non usage.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

7.Turn control knob counterclockwise to the PILOT position.

8.Push in control knob all the way and hold in. Immediately light the pilot by pressing the red ignitor button until a flame ap- pears. Continue to hold the control knob in for about (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after sev- eral tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

9.Turn gas control knob counterclockwise

to “ON”. Knob can be turned to “ON” only if the control knob is popped out.

10.Replace control access panel.

11.Turn on all electric power to the appliance.

Gas Control Knob

Position Indicator

Figure 23 - Millivolt Control Valve

55175G

www.fmiproducts.com