Fireplace
Installation
Continued
assembly underneath the front ledge. A 1/8" NPT plugged tapping is provided on the gas control valve for a test gauge connection immediately upstream of the gas supply connection to the appliance (see Figures 13 and 14).
|
| Pilot Gas Line |
|
| Pilot | Do Not Kink | To Pilot |
ON/OFF | Adjustment | Burner |
Knob Cap
Strain Relief
Common Grommet
Ground Wire
Figure 12 - Wiring Through Outer SurroundGAS SUPPLY TESTINGNote: This section is intended as a guide for qualified technicians installing gas to this appliance.
CAUTION: Do not connect appliance before pressure testing gas piping. Damage to gas valve may result and an unsafe condition may be caused.
The appliance and its individual
The appliance must be isolated from the gas supply piping system by closing its individual manual
This unit has been tested for installation at high altitude. Higher altitudes affect the atmospheric pressure and heat valve of gaseous fuels. When installing this unit at high altitudes, the rated input will be lower than at sea level. The lowered oxygen content in the air and the lowered gas density require installation of a different size orifice in order to achieve clean combustion of the unit. Consult the unit data plate for the proper
The gas control valve is secured to the burner pan
To Main
Burner
Inlet Outlet
Pressure Pressure
Figure 13 - Millivolt Control ValveTo
Main
Burner
From | E | A | |
Gas |
| Outlet | |
Supply | Inlet | ||
Pressure | |||
| Pressure | ||
|
|
WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.
WARNING: Before you pro- ceed,makesureyourgassupply is OFF.A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the ap- pliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 15, page 10.
A 30" long, 1/2" NPT SCHD 40 flexible gas line (supplied) may be used between the incoming 1/2" NPT black iron gas line and the fireplace regulator (located inside the firebox, under the access plate). The incoming gas line may be routed toward the appliance from either the left or right hand side of fireplace outer surround.