seRVICe HInTsWhen Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• replace will not produce specied heat
• propane/LP gas supply may be low (pro-
pane/LP only)
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TeCHnICal seRVICeYou may have further questions about
installation, operation, or troubleshooting.
If so, cont act FMI PROD UCTS, LL C a t
1-866-328-4537. When calling please have
your model and serial numbers of your
heater ready.
You can also visit our web site at
www.fmiproducts.com.
RePlaCeMenT PaRTsNote: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to
the factory.
VMH26TPC
• Rating (Variable): 14,000/26,000 Btu/Hr
• Gas Type: Propane/LP Gas Only
• Ignition: Piezo
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum* - 11" W.C.
* For purposes of input adjustment
For Both Models
• Dimensions (H x W x D) (including hood and screws):
Fireplace - 257/8" x 2613/16" x 93/8", Carton - 325/8" x 273/16" x 115/8"
• Weight: Fireplace - 44.5 lbs., Shipping - 48 lbs.
sPeCIFICaTIonsVMH26TNC
• Rating (Variable): 14,000/26,000 Btu/Hr
• Gas Type: Natural Gas Only
• Ignition: Piezo
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum* - 5" W.C.
* For purposes of input adjustment