![MOUNTING THE BUILT-IN COOKTOP](/images/new-backgrounds/73468/734687x1.webp)
MOUNTING THE BUILT-IN COOKTOP
Caution !
•To avoid any possible hazard, the appliance may be installed by qualified personnel only.
•Panels and furniture lining of the kitchen cabinet receiving the hob must be treated with temperature resistant adhesives 100°C (otherwise they might be discoloured or deformed because of inadequate temperature resistance).
•The cooking hob is intended for building into the worktop above the kitchen element of ≥600 mm depth.
After the installation of
•Suspended kitchen elements above the cooktop must be installed at such distance to provide enough room for comfortable working process.
•The distance between the worktop and the hood must be at least such as indicated in the instructions for installation of the kitchen hood, but in no case it may be less than 700 mm.
•The use of hard wood decorative borders around the worktop behind the appliance is allowed, in case the minimum distance remains as indicated on the installation illustrations.
•Minimum distance between the
Built-in induction hob opening dimensions
A | 590mm |
B | 520mm |
C | 560mm |
D | 490mm |
E | 53mm |
F | 10mm |
G | 50mm |
H | 5mm |
•Induction hob may be built into the 25 to 40 mm thick worktops.
•Bottom kitchen element must not have a drawer. It must be fitted with a horizontal plate 20 mm away from the worktop bottom surface. Space between the plate and the hob must be empty and no objects may be stored or kept there.
•Rear side of the kitchen element must also have a 50 mm high opening along the entire width of the element, and the front part must have an opening of no less than 5 mm.
•Incorporation of the oven under the induction hob is permissible for ovens equipped with a cooling fan.
Prior inserting the oven, it is necessary to remove the rear kitchen element panel in the area of the oven opening.
Equally, the front part of the element must have an opening of no less than 5 mm.
21