10
VF-16

4-4. Self Check

This menu automatically tests the following points in order.
1. SCSI port 2. ATA (E-IDE) bus 3. MIDI in/out circuit 4. S/P DIF digital signal in/out
5. ADAT digital signal in/out 6. Phantom power (+48V) 7. A/D and D/A circuit (Input Monitor)

4-3. DA Test

This menu is not currently working.
Even though the [ENTER/YES] key is pressed, the following is just displayed. To go on, press the [ENTER/YES] key.
CAUTION
AVIS:RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR
TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
ST OUTAUX SEND
RL
IN OUT
MIDI DIGITAL / DATA FOOT SW
IN OUT
SCSI POWER AC-IN
DIGITAL
MULTITRACKER

MIDI cable

Optical Cable

SCSI Cable

SCSI Drive (ZIP, MO, etc)

ID #: 1 ~ 6

< Cable connection when in “SelfCheck” mode >

In order to execute the “SelfCheck” test, connect the cables and SCSI drives as shown above. Then, press the [ENTER/
YES] key while the “SelfCheck” menu is selected.
CAUTION: In order not to form a MIDI signal loop, connect the MIDI cable IN and OUT after putting the VF-16 into
the Service Mode.