INSTALLATION - RECESSED
NOTE: If installing a
Recommended Blocking:
Wood double stud blocking is necessary. Contact an architect and
1" | 63 1/4" |
|
|
(1607 mm) |
|
| |
(25.4 mm) | 3 | 7/8" | TOP |
| |||
| (98.4 mm) | VIEW |
building official to make sure the blocking is adequate and complies with building codes (Fig. b).
For A. D. A. compliance, top of lower double stud MUST be 27“ (68.5 cm) from the floor.
1. Slide changer into blocking area and mark mounting hole location on blocking studs.
HINT: This may require 2 additional people to help hold changer in position while you are marking the locations.
63 1/4" (1607 mm)
Double Stud
Stud |
| |
Double | 19.4" | |
(492 mm) | ||
|
Double Stud
Double Stud
21 3/4" FRONT
(552 mm) VIEW
2. Shim changer for a snug fit.
3. Align holes in changer with marked holes and secure using the appropriate fasteners (Fig. c).
NOTE: It is installers responsibility to provide correct fastereners for other substrates.
4. Ensure all seven (7) fasteners are tight.
A. F. F | Fig. b |
|
|
| |
| Recess | Recess |
| Mounting | |
| Holes | Mounting |
| Recess | Holes |
|
| |
| Mounting |
|
| Holes |
|
INSTALLATION - SURFACE-MOUNT
Fig. c
Recommended Blocking:
If the walls do not have studs on center, then additional blocking is necessary (Fig. d).
Contact an architect or building contractor to make sure the blocking is adequate and complies with building codes.
For A. D. A. compliance, measure up 48 1/2” (123 cm) from the floor and mark the wall. This locates the position for the top left attachment hole.
NOTE:- Changer MUST be mounted to studs (Fig. e).
- This unit incorporates a finishing collar that seats behind the changer’s outside flange. Center the collar as the unit is being tightened against the wall (Fig. f).
For A. D. A.
Compliance
48 1/2”
(123 cm)
A. F. F
143/4
(374.7 mm)
Top
48"
(1219 mm)
on center
Fig. d
Holes
CollarSurface-Mount Holes
Wall
2
Unit
Fig. f | Fig. e |
|