For A. D. A.
Compliance
27”
(68.5 cm)

INSTALLATION - RECESSED

NOTE: If installing a surface-mount changing station, see “Installation - Surface-Mount” section.

Recommended Blocking:

Wood double stud blocking is necessary. Contact an architect and

1"

63 1/4"

 

 

(1607 mm)

 

 

(25.4 mm)

3

7/8"

TOP

 

 

(98.4 mm)

VIEW

building official to make sure the blocking is adequate and complies with building codes (Fig. b).

For A. D. A. compliance, top of lower double stud MUST be 27“ (68.5 cm) from the floor.

1. Slide changer into blocking area and mark mounting hole location on blocking studs.

HINT: This may require 2 additional people to help hold changer in position while you are marking the locations.

63 1/4" (1607 mm)

Rough-in

Double Stud

Stud

 

Double

19.4"

(492 mm)

 

Double Stud

Double Stud

21 3/4" FRONT

(552 mm) VIEW Rough-in

2. Shim changer for a snug fit.

3. Align holes in changer with marked holes and secure using the appropriate fasteners (Fig. c).

NOTE: It is installers responsibility to provide correct fastereners for other substrates.

4. Ensure all seven (7) fasteners are tight.

A. F. F

Fig. b

 

 

 

 

Recess

Recess

 

Mounting

 

Holes

Mounting

 

Recess

Holes

 

 

 

Mounting

 

 

Holes

 

INSTALLATION - SURFACE-MOUNT

Fig. c

Recommended Blocking:

If the walls do not have studs on center, then additional blocking is necessary (Fig. d).

Contact an architect or building contractor to make sure the blocking is adequate and complies with building codes.

For A. D. A. compliance, measure up 48 1/2” (123 cm) from the floor and mark the wall. This locates the position for the top left attachment hole.

NOTE:- Changer MUST be mounted to studs (Fig. e).

- This unit incorporates a finishing collar that seats behind the changer’s outside flange. Center the collar as the unit is being tightened against the wall (Fig. f).

For A. D. A.

Compliance

48 1/2”

(123 cm)

A. F. F

143/4

(374.7 mm)

Top

48"

(1219 mm)

on center

Fig. d

Surface-Mount

Holes

CollarSurface-Mount Holes

Wall

2

Unit

Fig. f

Fig. e

 