Test Telephones and Other Equipment

6.At the test telephone, hang up the receiver.

7.On the attendant console, press Night key.

8.Verify Night lamp goes dark.

ProcedureRinging Device Not Installed

1.Connect a spare 2500-type telephone to the information outlet indicated on the console parameters screen.

2.On the attendant console, press Night key.

3.Verify Night lamp lights.

4.Select a working telephone as the test telephone.

5.At the test telephone, pick up the receiver, dial a trunk access code and the listed directory number for the attendant console.

6.Verify ringing is heard on the spare telephone.

7.At the test telephone, hang up the receiver.

8.Disconnect the spare telephone from the information outlet.

9.Press the Night key on the attendant console.

10.Verify the Night lamp goes off.

11.Notify the customer that installation is complete and the external ringing device can be installed.

Test Queue Warning Indicator

Description

Make a test call to an extension associated with a Uniform Call Distribution (UCD) or Direct Department Calling (DDC) group, and verify the queue warning indicator lamp lights. If the queue warning indicator has not yet been installed by customer, connect a spare telephone to the information outlet reserved for queue warning indicator and make a test call.

ProcedureQueue Warning Indicator Installed

1.Administer Queue Warning Indicator number to 0 on Hunt Group Screen. Record old number.

2.Make sure all telephones in the group are disconnected or are “busy.”

3.Select a working telephone as the test telephone.

10-10Issue 1 September 1995

Page 206
Image 206
AT&T 555-230-894 manual Test Queue Warning Indicator, Procedure- Ringing Device Not Installed