Option Switch Settings

Refer to "Interface Cabling to Station Message Detail Recording (SMDR) Output Device" on page 9-63for connection information.

The 475 or 572 printers can be used as an output receiving device for station message detail recording (SMDR). The recommended option settings for these printers are shown in the following tables. Also, a TELESEER, station message detail recording (SMDR), 94A Local Storage Unit (LSU), or Customer Premises Equipment (CPE) can be used as the output receiving device. Administration procedures for station message detail recording (SMDR) (MPDM) equipment are provided in DEFINITY Communications System Generic 3 Implementation, 555-230-653.

Table H-24. Option Switch Settings on Modular Processor Data Module (MPDM) or Modular Trunk Data Module (MTDM) for Station Message Detail Recording (SMDR)

Switch

Setting

 

 

 

SELF TEST

OFF

 

 

 

LOC LOOP/REM LOOP

OFF

 

 

 

1200 BAUD

ON

 

 

 

AANS (modular

ON

processor data module

 

 

Only)

 

 

 

 

 

SIGLS

ON

 

 

 

PRTY

ON

 

 

 

I/OD

ON

 

 

 

All Others

OFF

 

 

 

 

 

 

Table H-25. Option Switch Settings on 212-Type Modem for Station Message Detail Recording (SMDR)

Switch

Setting

 

AL

OFF

 

 

 

ST

OFF

 

 

 

RDL

OFF

 

 

 

DL

OFF

 

 

 

HS

ON

 

 

 