475 or 476 Printer Used as Journal Printer for Hospitality Feature
Table
Section | Setting | Description |
|
|
|
|
| Switch 22 |
|
|
|
1 | OFF | Baud Rate* |
|
|
|
2 | ON |
|
|
|
|
3 | ON |
|
|
|
|
4 | OFF | Not Used |
|
|
|
|
| Switch 23 |
|
|
|
1 | ON | RS232 |
|
|
|
2 | OFF |
|
|
|
|
3 | OFF | Use of DSR |
|
|
|
4 | OFF |
|
|
|
|
5 | ON |
|
|
|
|
6 | OFF | Not Used |
|
|
|
|
| Switch 24 |
|
|
|
1 | ON | Select DTR Timing |
|
|
|
2 | ON |
|
|
|
|
3 | OFF | Select RTS Timing |
|
|
|
4 | ON |
|
|
|
|
5 | ON | Use of CTS |
|
|
|
6 | OFF |
|
|
|
|
7 | OFF |
|
8ON
*The Baud Rate Default is 1200 baud. Any speed can be used, but the speed of the printer and any connection device used must match.