Determine the Location of the Equipment Closets

NOTE:

Check location of the AC power receptacle. The receptacle must be on a separately current limited (fuse or circuit breaker) circuit not controlled by a wall switch.

Determine the Location of the

Equipment Closets

Determine the location of the equipment closets where large cables can be connected out into smaller ones. Determine locations of terminating resisters for Basic Rate Interface (BRI) station circuits to be installed in equipment closets.

Determine External Trunk Locations

Determine where external trunk lines come into the building and be routed to the equipment room. Determine where external trunk converters and adapters as well as sneak-current fuse panels will be installed in the switch room (preferably close or next to the cross connect fields).

Create a Provisioning Plan

Determine an appropriate available port circuit on the DEFINITY System for each telephone, trunk, and peripheral connection needed, and, in addition, plan for auxiliary power for Basic Rate Interface (BRI) and certain display sets.

Create a provisioning plan to include the following (see the example on the following page):

Station or trunk type or feature/service.

Building location (floor/room/desk/information outlet).

Extension number or trunk group and member number.

Port circuit location on the switch for each endpoint (DEFINITY System Generic 3 cabinet/carrier/slot/circuit.

Route from switch room through equipment closets to each endpoint.

Auxiliary power supply, if required.

Issue 1 September 1995 2-9

Page 35
Image 35