Wire the 1146B1 Power Distribution Unit

It may be better to wire endpoints to the 1146B1 while power from the 1145B1 is on. This way, a red light emitting diode (LED) on the distribution unit lights if you connect its associated circuit to shorted building wiring or to a shorted terminal.

1.Install cross-connect jumpers to wire from the Distribution Unit (the label shows polarity) to Pins 7 and 8 of the appropriate information outlet. Route the wires through the clip provided on the unit. If a red light emitting diode (LED) is on, see the next section Reset light emitting diodes (LED) on Power Distribution Unit. The following illustration shows a typical connection.

2.Mark lead destination on the label next to each connector on the Distribution Unit. Also mark the Unit Number and Connectivity information on the label.

1

4

5

7

1 17

6

16

32

3

2

10

8

9

9

12

11

Figure Notes:

1.

Alternating Current (AC)

8.

Private branch exchange Port Circuit

2.

Installer-provided ground wire

9.

Tip and Ring

3.

Circuits 1-32

10.

Pins 7 & 8

4.

Power supply kit

11.

Cross-Connect

5.

Battery

12.

Integrated Services Digital Network

6.

1145B1 Power Supply

 

(ISDN)/ Display System Protocol (DSP)

 

Terminal

 

 

 

7.

1146B1 Distribution Unit

 

 

Figure 9-14. Typical Wiring to a Terminal

9-32Issue 1 September 1995

Page 162
Image 162
AT&T 555-230-894 manual Wire the 1146B1 Power Distribution Unit, Typical Wiring to a Terminal