Test Time Division Multiplexer (TDM) for each

Expansion Port Network (EPN)

 

 

TEST RESULTS

 

 

Port

Maintenance Name

Alt. Name Test No. Result

Error Code

02A01

EXP-INTF

237

PASS

 

02A01

EXP-INTF

238

PASS

 

02A01

EXP-INTF

240

PASS

 

02A01

EXP-INTF

241

PASS

 

02A01

EXP-INTF

244

PASS

 

02A01

EXP-INTF

316

PASS

 

 

 

 

 

 

Screen 8-14. Example Test Results for Expansion Interface Board 2A01

If any result is FAIL, check the connections for the associated fiber optic link.

4. Repeat Steps 2 and 3 for each expansion interface board in the system.

Test Time Division Multiplexer (TDM) for each Expansion Port Network (EPN)

Check each Time Division Multiplexer (TDM) for each Expansion Port Network (EPN) in the system.

1.Verify the screen displays: command:

2.Type test tdm port-network 2 and press ENTER.

3.Verify a test results screen similar to the one below is displayed:

Issue 1 September 1995 8-15

Page 125
Image 125
AT&T 555-230-894 manual Type test tdm port-network 2 and press Enter