Install and Wire Telephones and Other Equipment

Table 9-3. Wiring Example of Analog Station 2500 to TN2183

Analog Line

 

 

TN2183 Analog Line,

 

Analog Station 2500

Position 1C01

 

 

Pin (2-pair modular)

Name

Port 3 Name

 

Pin

 

2

T

T3

 

28

 

3

R

R3

 

03

 

 

 

 

 

 

 

The following diagram illustrates these wiring designations.

 

1

 

2

3

4

5

3

2

T

T3

28

3

R

R3

03

Figure Notes:

1.

Analog Station 2500

4.

Name

2.

TN2183 Analog Line, position 1C01

5.

Port 3 Name

3.

Pin Number

 

 

Figure 9-4. Analog Station 2500 to TN2183 Analog Line Wiring

Example

Analog Tie Trunk Example

Steps 1-3 of each example should have been completed in the Provisioning Plan in Chapter 2, "Plan and Prepare the Site", Step 8.

This example shows how to connect analog tie trunk wiring from one DEFINITY System Generic 3 to another DEFINITY System Generic 3:

1.Choose a peripheral to connect (such as Tie Trunk).

2.Choose the port circuit pack to use and its carrier and slot number. (such as TN760, Cabinet 1, Carrier C, Slot 05).

9-6Issue 1 September 1995

Page 136
Image 136
AT&T 555-230-894 manual Analog Tie Trunk Example, Analog Station 2500 to TN2183 Analog Line Wiring Example