Test Telephones and Other Equipment
Procedure
1.At control carrier, set Emergency Transfer switch(es) to ON position. See Note.
NOTE:
Pull out on Switches to overcome detents.
2.At emergency transfer telephone connected to the port network being tested, pick up the receiver and press Ground Start key, if so equipped. Dial tone is heard.
3.Dial number associated with an outside number. Audible ringing or busy tone is heard.
4.Hang up the test telephone.
5.At control carrier, set Emergency Transfer switch(es) to AUTO position.
Test Remote Access Interface (known
as Initialization and Administration
System)
Description
Test the communication link between the switch and Initialization and Administration System (INADS) and verify the alarm notification process. Make a remote test from Initialization and Administration System (INADS) to the system and a local test from the system to Initialization and Administration System (INADS).
NOTE:
In some countries, this remote access interface is not allowed. Check with your AT&T representative.
Procedure— Remote Test
1.Call outside personnel who will be accessing the switch remotely to perform administration, maintenance, and testing.
2.Ask remote access personnel to call system and login and display System Parameters Maintenance screen. The login must be successful.
NOTE:
Requirement: Product Identification on the System Parameters screen must match the Product Identification administered by the local technician.