Test the System

 

 

 

TEST RESULTS

 

 

Port

Maintenance Name

Alt. Name Test No. Result

Error Code

 

SHDW-LNK

 

318

PASS

 

Command successfully

completed

 

 

 

 

 

 

 

 

 

Screen 8-11. Example Test Results for Switch Processing Element Duplication Memory Shadowing Link

4.If result is FAIL for any test, check the Inter-Cabinet Cables (ICC) in the Processor Port Network (PPN).

Test Duplicated Switch Processing

Element (SPE) Interchange

For High and Critical Reliability systems, check the Switch Processing Element (SPE) interchange.

1.Verify the screen displays: command:

2.Type status system all-cabinets and press ENTER.

3.Verify the screen displays test results similar to the example shown on the following page:

8-12Issue 1 September 1995

Page 122