Option Switch Settings
!CAUTION:
To prevent damage from static electricity, always wear an EMC wrist strap (comcode 900 698 226) when handling circuit packs or other switch components.
Table H-27. Signaling Formats for TN760
Mode | Type | |
|
|
|
E & M | Type I Standard (unprotected) | |
|
|
|
E & M | Type I Compatible (unprotected) | |
|
|
|
Protected | Type I Compatible, Type I Standard | |
|
|
|
Simplex | Type V | |
|
|
|
E&M | Type V | |
|
|
|
E&M | Type V Revised | |
|
|
|
|
|
|
Table
Signaling | Transmit (M Lead) | Receive (E Lead) | ||
|
|
|
| |
Type | ||||
|
|
|
|
|
Type I | grd | bat | open*/bat | grd |
Standard |
|
|
|
|
|
|
|
|
|
Type I | open*/bat | grd | grd | open*/bat |
Compatible |
|
|
|
|
|
|
|
|
|
Type V | open/bat* | grd | open | grnd |
|
|
|
|
|
Type V | grd | open | grd | open |
Reversed |
|
|
|
|
|
|
|
|
|
* An open circuit is preferred over voltage.