Foundations 100-SSV, SI260D manual Installation Recessed, Installation SURFACE-MOUNT

Models: SI260D 100-SSV

1 3
Download 3 pages 24.06 Kb
Page 3
Image 3

INSTALLATION - RECESSED

 

 

 

 

For A. D. A. compliance, top of lower double stud should be

 

1"

22-1/2"

 

 

 

30.5“ (78 cm) from the floor.

(25.4 mm)

(571 mm)

 

 

 

 

 

 

 

 

 

Recommended Blocking:

 

 

 

 

3-7/8"

TOP

 

 

 

 

(98.6 mm)

VIEW

Wood double stud blocking is necessary. Contact an architect and

 

 

 

 

 

 

22-1/2" (571 mm)

 

 

building official to make sure the blocking is adequate and complies

 

 

 

 

 

 

Double Stud

 

 

 

with building codes (Fig. b).

 

 

Rough-in

 

 

 

 

 

 

 

 

 

1. Slide changer into blocking area and mark mounting hole location

 

 

 

 

34-1/8"

FRONT

on blocking studs.

 

DoubleStud

30-1/2”

DoubleStud

(867 mm)

VIEW

HINT: This may require 2 additional people to help hold changer

 

Rough-in

 

in position while you are marking the locations.

 

 

(775 mm)

 

 

 

2. Shim changer for a snug fit.

 

 

 

 

 

 

3. Align holes in changer with marked holes and secure using the

 

 

 

 

 

 

appropriate fasteners (Fig. c).

For A. D. A.

 

Double Stud

 

 

 

NOTE: It is installers responsibility to provide correct fastereners

(78 cm)

 

 

 

 

 

 

Compliance

 

 

Fig. b

 

 

for other substrates.

30.5”

 

 

 

 

 

A. F. F

 

 

 

4. Ensure all six (6) fasteners are tight.

 

 

 

Recess

 

Recess

 

 

 

Mounting

 

 

 

Recess

Holes

 

Mounting

 

 

 

 

 

Holes

 

 

Mounting

 

 

 

 

 

 

Holes

 

 

 

INSTALLATION - SURFACE-MOUNT

Fig. c

Recommended Blocking:

If the walls do not have studs on center, then additional blocking is necessary (Fig. d).

Contact an architect or building contractor to make sure the blocking is adequate and complies with building codes.

For A. D. A. compliance, measure up 62 3/4” (159 cm) from the floor and mark the wall. This locates the position for the top left attachment hole.

NOTE:- Changer MUST be mounted to studs (Fig. e).

- This unit incorporates a finishing collar that seats behind the changer’s outside flange. Center the collar as the unit is being tightened against the wall (Fig. f).

Collar

Top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16"

 

 

 

 

 

26"

 

 

 

 

 

 

For A. D. A.

 

(660 mm)

 

 

 

(406 mm)

 

 

 

Compliance

 

on center

 

 

 

on center

 

 

62 3/4”

 

 

 

 

 

 

 

 

 

 

 

(159 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. F. F

 

 

 

 

 

 

 

 

 

 

 

Fig. d

 

 

 

 

 

 

 

 

 

 

 

 

 

Surface-Mount

 

 

 

 

 

 

 

Holes

Wall

2

Unit

 

Fig. f

Fig. e

 

Page 3
Image 3