RECIRCULATION VERSION AIR OUTLET

Mounting the hood body

 

Vr

• Before attaching the hood body, tighten the two screws Vr lo-

 

 

cated on the hood body mounting points.

 

 

• Hook the hood body onto the screws 12a.

 

 

• Fully tighten support screws 12a.

 

 

• Adjust screws Vr to level the hood body.

12a

 

 

 

Connections

 

 

DUCTED VERSION AIR EXHAUST SYSTEM

 

 

When installing the ducted version, connect the hood to the

ø 150

ø 120

chimney using either a flexible or rigid pipe ø 150 or 120 mm,

 

9

the choice of which is left to the installer.

 

 

• To install a ø 120 mm air exhaust connection, insert the re-

 

 

ducer flange 9 on the hood body outlet.

 

 

Fix the pipe in position using sufficient pipe clamps (not sup- plied).

Remove any activated charcoal filters.

14.1

 

RECIRCULATION VERSION AIR OUTLET

 

Put connection 15 into the connection support 7.3.

 

Insert the connection extension pieces laterally 14.1 in connec-

15

 

tion 15.

 

Make sure that the outlet of the extension pieces 14.1 is hori-

ø 150

 

zontally and vertically aligned with the chimney outlets.

Connect the air outlet connection 15 to the hood body outlet

 

 

using either a flexible or rigid pipe ø 150 mm, the choice of

 

 

which is left to the installer.

 

• Ensure that the activated charcoal filters have been inserted.