Omron Healthcare VARISPEEDF7 EN-8, ‹ Electrical Connection „Wiring the Inverter, Wiring Diagram

Models: VARISPEEDF7

1 25
Download 25 pages 7.4 Kb
Page 9
Image 9

‹Electrical Connection

„Wiring the Inverter

 

 

Main Contactor

 

 

T

 

 

Fuses

3-phase power

L1

Line

380 to 480 V

L2

50/60 Hz

Filter

L3

 

 

 

PE

 

DC reactor to improve input

 

power factor (optional)

Braking resistor unit (optional)

 

Short-circuit bar

2

1

B1

B2

R/L1

U/T1

 

S/L2

V/T2

M

T/L3

W/T3

 

 

Varispeed F7

 

Forward Run / Stop

Reverse Run / Stop

S1

S2

MA

Fault relay output

MB 250 VAC, 1 A max.

External Fault Fault reset

S3

S4

MC

30 VDC, 1 A max.

Multi-function digital inputs [Factory setting]

Multi-step speed setting 1

Multi-step speed setting 2

Jog frequency selection

S5

S6

S7

SN

SC

SP

24 V

E(G)

Shield terminal

M1

M2

Relay output 1

[Default: Running]

 

M3

Relay output 2

 

M4

[Default: Zero speed]

M5

Relay output 3

 

M6

[Default:

Frequency agree 1]

2CN

Multi-function digital output 250 VAC, 1 A max.

30 VDC, 1 A max.

RP Pulse train input [Default:

 

 

 

Frequency reference input]

 

Analog input setting

 

0 to 32 kHz

 

 

 

 

adjustment

 

+V Analog input power supply

 

 

 

 

 

2 kΩ

15 V, 20 mA

 

 

 

2 kΩ

0 to 10 V

 

A1 Analog input 1: Master

 

 

frequency reference

 

 

 

0 to 10 V (20 kΩ)

 

4 to 20 mA

 

A2 Multi-function analog input 2

 

 

 

[Default: Frequency bias

 

P

P

4 to 20 mA (20 kΩ)]

 

AC

 

 

 

 

 

 

0 V

 

 

 

-V Analog input power supply

PG

Option

Card

-15 V, 20 mA

Input

 

Option

2CN

Card

 

Terminating

 

resistance

R+

 

P

 

Shield terminal

E(G)

MP

AC

FM

Pulse train output

0 to 32 kHz (2.20 kΩ) [Default: Output frequency]

Adjustment, 20 kΩ

+

-

Multi-function analog output 1

 

FM

(-10 to +10 V, 2 mA / 4 to 20 mA)

 

 

[Default: Output frequency, 0 to 10 V)

 

 

4 to 20 mA (20 kΩ)]

Adjustment, 20 kΩ

 

 

R-

MEMOBUS

 

 

communication

 

S+

RS-485/422

 

P

 

 

S-

 

 

+

-

Multi-function analog output 2

AM

AM

(-10 to +10 V, 2 mA / 4 to 20 mA)

 

AC

 

[Default: Output current, 0 to 10 V)

 

4 to 20 mA (20 kΩ)]

IG

Shielded wires

P

Twisted-pair shielded wires

Fig 4 Wiring Diagram

EN-8

Page 9
Image 9
Omron Healthcare VARISPEEDF7 specifications EN-8, ‹ Electrical Connection „Wiring the Inverter, Wiring Diagram