Omron Healthcare VARISPEEDF7 specifications EN-10, During run no Closed during Run Function

Models: VARISPEEDF7

1 25
Download 25 pages 7.4 Kb
Page 11
Image 11

Type

No.

Signal Name

Function

 

Signal Level

 

M1

During run (NO)

Closed during Run

 

 

 

 

 

 

 

 

 

M2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

signals

M3

 

Closed when output

 

 

 

Zero speed (NO)

frequency at zero level

 

selected by H2-

Relay contacts

M4

 

output

 

 

(b2-01) or below

 

01 to H2-03

Contact capacity:

 

 

 

 

 

M5

Speed agreement detection

Within ± 2 Hz of set fre-

 

 

1 A max. at 250 VAC

 

(NO)

quency when ON

 

 

1 A max. at 30 VDC*3

Digital

M6

 

 

 

 

 

 

 

 

MA

 

Closed across MA and MC during faults

 

 

 

 

 

 

MB

Fault output signal

 

 

Open across MB and MC during faults

 

 

 

 

 

 

MC

 

 

 

 

 

 

 

 

 

 

 

signals

 

 

Analog output fre-

 

Function

0 to +10 V max. ±5%

FM

Output frequency

quency signal;

 

selected by

 

 

0 to 10 V; 10V=FMAX

 

H4-01

2 mA max.

 

 

 

 

 

 

output

AC

Analog common

 

-10 to +10 V max. ±5%

 

 

 

 

 

 

 

Analog output power

 

Function

2 mA max

Analog

 

 

signal;

 

 

AM

Inverter output power

 

selected by

 

0 to 10V; 10V=max.

 

4 to 20 mA

 

 

 

H4-04

 

 

appl. motor capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H6-01 (Frequency reference input) *4

0 to 32 kHz (3kΩ)

I/O

RP

Pulse Input

High level voltage 3.5 to

 

 

 

 

 

13.2 V

Pulse

 

 

 

 

 

 

 

 

 

 

 

MP

Pulse Output

H6-06 (Output frequency)

0 to 32 kHz

 

+15 V output (2.2kΩ)

 

 

 

 

 

 

 

 

 

 

 

 

 

-485/422

R+

MEMOBUS communications

 

 

 

Differential input,

 

input

 

PHC isolation

R-

For 2-wire RS-485, short R+ and S+

 

 

as well as R- and S-.

 

 

S+

MEMOBUS communications

 

Differential input,

 

output

 

 

 

PHC isolation

RS

S-

 

 

 

 

 

 

 

 

 

 

IG

Signal common

 

 

 

 

 

 

 

 

*1. The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi- step speed setting

1 for S6 and multi-step speed setting 2 for S7.

*2. Do not use this power supply for supplying any external equipment.

*3. When driving a reactive load, such as a relay coil with DC power supply, always insert a flywheel diode as shown in Fig 6

*4. Pulse input specifications are given in the following table:

Low level voltage

0.0 to 0.8 V

 

 

High level voltage

3.5 to 13.2 V

 

 

H duty

30% to 70%

 

 

Pulse frequency

0 to 32 kHz

 

 

Flywheel diode

External power:

Coil

30 VDC max.

1 A max.

The rating of the flywheel diode must be at least as high as the circuit volt- age.

 

 

 

Fig 6 Flywheel Diode Connection

 

 

In Fig 4 the wiring of the digital inputs S1 to S7 is shown for the connection of contacts or NPN transis-

 

 

1.

 

 

 

tors (0V common and sinking mode). This is the default setting.

 

 

 

For the connection of PNP transistors or for using a 24V external power supply, refer to Table 3.

IMPORTANT

 

2.

A DC reactor is an option only for Inverters of 18.5 kW or less. Remove the short circuit bar when con-

 

 

 

necting a DC reactor.

 

 

 

 

EN-10

Page 11
Image 11
Omron Healthcare VARISPEEDF7 specifications EN-10, During run no Closed during Run Function, Flywheel Diode Connection

VARISPEEDF7 specifications

The Omron Healthcare VARISPEEDF7 is an innovative and advanced medical device designed to provide effective therapy for various health conditions. This cutting-edge device is part of Omron’s commitment to enhancing healthcare solutions and promoting patient well-being through technology. The VARISPEEDF7 is particularly notable for its versatility and effectiveness in various therapeutic applications.

One of the main features of the VARISPEEDF7 is its adjustable speed settings. This allows healthcare professionals to customize the therapy according to the specific needs of each patient. The ability to vary speed enhances treatment effectiveness, as different conditions may require different intensities. The device is designed to accommodate a wide range of therapeutic needs, making it a valuable tool in clinical and home healthcare settings alike.

The VARISPEEDF7 integrates several advanced technologies, including its proprietary motor control system. This system provides smooth and consistent operation, minimizing disruptions during therapy sessions. The technology ensures precise speed control, enabling healthcare providers to maintain optimal conditions for therapy.

In addition to its speed control, the VARISPEEDF7 is equipped with a user-friendly interface. The display provides clear information about settings and progress, making it easy for both healthcare professionals and patients to monitor treatment sessions. The intuitive design reduces the learning curve and enhances the overall user experience.

Another significant characteristic of the VARISPEEDF7 is its portability. The compact design allows for easy transport and storage, making it ideal for patients who require therapy at home or on the go. This feature is particularly beneficial for individuals with mobility issues or those who enjoy an active lifestyle.

Durability is also a hallmark of the VARISPEEDF7. It is built with high-quality materials that ensure longevity and reliability, even with frequent use. This commitment to durability highlights Omron’s dedication to providing healthcare solutions that practitioners and patients can trust.

In summary, the Omron Healthcare VARISPEEDF7 represents a significant advancement in therapeutic technology. With its adjustable speed settings, advanced motor control system, user-friendly interface, portability, and durability, the VARISPEEDF7 is designed to meet the diverse needs of patients and healthcare providers. It stands out as a versatile solution that enhances patient care and promotes effective treatment outcomes. As healthcare continues to evolve, the VARISPEEDF7 exemplifies how innovative technologies can make a substantial impact on health and well-being.