Omron Healthcare VARISPEEDF7 EN-14, ‹ Digital Operator Display optional, „Digital Operator Keys

Models: VARISPEEDF7

1 25
Download 25 pages 7.4 Kb
Page 15
Image 15

Keypad Operation

‹Digital Operator Display (optional)

The key names and functions of the Digital Operator are described below

Drive Mode Indicators

FWD: Lights up when a forward run command is input.

REV: Lights up when a reverse run command is input.

SEQ: Lights up when any other run command source than the Digital Operator is selected.

REF: Lights up when any other frequency reference source than the Digital Operator is selected.

ALARM: Lights up when an error or alarm has occurred.

Data Display

Displays monitor data, parameter numbers, and set- tings.

Mode Display (displayed at the upper left of the data display

DRIVE: Lights up in Drive Mode.

QUICK: Lights up in Quick Programming Mode.

ADV: Lights up in Advanced Programming Mode.

VERIFY:Lights up in Verify Mode.

A. TUNE:Lights up in Autotuning Mode.

Keys

Execute operations such as setting user parameters, monitoring, jogging, and autotuning.

„Digital Operator Keys

Key

Name

Function

 

 

Switches between operation via the Digital Operator (LOCAL) and

 

LOCAL/REMOTE Key

the settings in b1-01 and b1-02 (REMOTE).

 

 

This key can be enabled or disabled by setting parameter o2-01.

 

 

 

 

MENU Key

Selects the modes.

 

 

 

 

ESC Key

Returns to the status before the DATA/ENTER Key was pressed.

 

 

 

 

JOG Key

Enables jog operation when the Inverter is being operated from the

 

Digital Operator.

 

 

 

 

 

 

FWD/REV Key

Selects the rotation direction of the motor when the Inverter is being

 

operated from the Digital Operator.

 

 

 

 

 

 

Shift/RESET Key

Sets the active digit when programming user parameters.

 

Also acts as the Reset key when a fault has occurred.

 

 

 

 

 

 

 

Selects user parameter numbers and increments parameter set-

 

Increment Key

tings.

 

 

Used to move to the next item or data.

 

 

 

 

 

Selects user parameter numbers and decrements parameter set-

 

Decrement Key

tings.

 

 

Used to move to the previous item or data.

 

 

 

 

DATA/ENTER Key

Enters menus and parameters and validates parameter settings.

 

 

 

 

RUN Key

Starts operation when the Inverter is being controlled by the Digital

 

Operator (LOCAL Mode).

 

 

 

 

 

 

 

Stops Inverter operation (LOCAL and REMOTE Mode).

 

STOP Key

This key can be enabled or disabled when operating from a source

 

 

different tan the operator by setting parameter o2-02.

 

 

 

EN-14

Page 15
Image 15
Omron Healthcare VARISPEEDF7 specifications EN-14, ‹ Digital Operator Display optional, „Digital Operator Keys

VARISPEEDF7 specifications

The Omron Healthcare VARISPEEDF7 is an innovative and advanced medical device designed to provide effective therapy for various health conditions. This cutting-edge device is part of Omron’s commitment to enhancing healthcare solutions and promoting patient well-being through technology. The VARISPEEDF7 is particularly notable for its versatility and effectiveness in various therapeutic applications.

One of the main features of the VARISPEEDF7 is its adjustable speed settings. This allows healthcare professionals to customize the therapy according to the specific needs of each patient. The ability to vary speed enhances treatment effectiveness, as different conditions may require different intensities. The device is designed to accommodate a wide range of therapeutic needs, making it a valuable tool in clinical and home healthcare settings alike.

The VARISPEEDF7 integrates several advanced technologies, including its proprietary motor control system. This system provides smooth and consistent operation, minimizing disruptions during therapy sessions. The technology ensures precise speed control, enabling healthcare providers to maintain optimal conditions for therapy.

In addition to its speed control, the VARISPEEDF7 is equipped with a user-friendly interface. The display provides clear information about settings and progress, making it easy for both healthcare professionals and patients to monitor treatment sessions. The intuitive design reduces the learning curve and enhances the overall user experience.

Another significant characteristic of the VARISPEEDF7 is its portability. The compact design allows for easy transport and storage, making it ideal for patients who require therapy at home or on the go. This feature is particularly beneficial for individuals with mobility issues or those who enjoy an active lifestyle.

Durability is also a hallmark of the VARISPEEDF7. It is built with high-quality materials that ensure longevity and reliability, even with frequent use. This commitment to durability highlights Omron’s dedication to providing healthcare solutions that practitioners and patients can trust.

In summary, the Omron Healthcare VARISPEEDF7 represents a significant advancement in therapeutic technology. With its adjustable speed settings, advanced motor control system, user-friendly interface, portability, and durability, the VARISPEEDF7 is designed to meet the diverse needs of patients and healthcare providers. It stands out as a versatile solution that enhances patient care and promotes effective treatment outcomes. As healthcare continues to evolve, the VARISPEEDF7 exemplifies how innovative technologies can make a substantial impact on health and well-being.