Mounting the hood body

Vr

• Before attaching the hood body, tighten the two screws Vr lo-

 

cated on the hood body mounting points.

 

• Hook the hood body onto the screws 12a.

 

• Fully tighten support screws 12a.

 

• Adjust screws Vr to level the hood body.

12a

 

Note: The Hood body should be secured to wall studs. If neces- sary, install a wood support behind the dry wall, flush mounted between 2 studs. This will provide the necessary structure and support for mounting.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using a rigid 6” duct.

Install the damper 10 ø 6”.

Fix the duct in position using sufficient pipe clamps (not sup- plied).

DUCTLESS VERSION AIR OUTLET

Put connection 15 into the connection support 7.3.

Insert the connection extension pieces laterally 14.1 in connec- tion 15.

Make sure that the outlet of the extension pieces 14.1 is hori- zontally and vertically aligned with the chimney outlets.

Connect the air outlet connection 15 to the hood body outlet using a rigid ø 6” duct. (not supplied)

Ensure that the activated charcoal filters have been inserted.

10

14.1

15

EN

 

9

 

9

Page 9
Image 9
Franke Consumer Products FDF 364 W Mounting the hood body, Connections, Ducted Version AIR Exhaust System