REASSEMBLY

REASSEMBLY

N.B. To avoid reassembling the wrong way round, the two fans have different couplings.

Reassemble the fans on the corresponding pins, pressing them until they snap into place.

Fit the protection grilles so that the teeth coincide in the “FREE” position and when turned to “LOCK”.

Replace the EASY CLEANING suction unit on the hood, inserting it in position and connecting it to the support pins.

Turn the lock levers, or screw in the lock plugs.

Connect the power connector and the command connector to the sockets on the sides of the suction device.

Replace any activated charcoal odour fil- ters.

Replace the grease filters.

Connect the hood to the power supply sys- tem, by turning the two-pole switch on the mains power line to on, or by turning the main switch on.

Check that the hood is working properly, by turning the motor and lighting on.