Franke Consumer Products LB2200 manual Installation, Care and Maintenance, Spare Parts & Warranty

Models: LB2200 LB3200 LB4200

1 2
Download 2 pages 34.34 Kb
Page 2
Image 2
Installation, Care and Maintenance

Franke Little Butler

Installation, Care and Maintenance

Franke Little Butler

Spare Parts & Warranty

Overview of Installation

There are three main components to the system, the dispensing head, the canister and the heating tank. The dispensing head comes with three 1/4” copper tubes and one silicone tube. The two shorter (12”) copper tubes are connected to the incoming water supply via the canister. The supply to the cold side may be diverted through a chiller before the dispensing head, if required. The longer (18”) copper tube is connected to the inlet of the tank. The silicone tube is connected to the outlet of the tank using the hose connector.

Preparing for the Installation

As with any sink related device, it is much easier to mount the dispensing head of this system onto the sink before the sink is mounted into the countertop. A mounting hole of 1 3/8” diameter (standard sink ledge drilling) is required.

It is always recommended to take the components and locate their optimum positions before starting the installation.

IMPORTANT: Do not plug in the unit until all water connections have been made and the tank is filled completely.

Making the Supply Provision

Provide a branch compression connection for a 3/8” supply tube. This should be done with a conventional tee and the shut-off valve provided. Flush the pipework before installing.

Troubleshooting

Should your dispenser not work correctly, check the list below before calling for service. The following things are not covered by the warranty.

[WARNING! Do not operate both levers at the same time as this can build up pressure in the heating tank causing the bladder to expand and eventually burst. Such damage is not covered by the warranty]

Water is not hot:

Check if electrical supply to heating tank is plugged in. Turn temperature control knob clockwise as far as possible.

Test the temperature again after 15 minutes. Check if fuse is blown or circuit breaker is open.

Hot water continuously drips or sputters from spout:

For safety reasons this faucet may drip or splutter after use. This venting prevents a build-up of pressure in the heating tank. If this becomes excessive; Turn the control knob counter-clockwise to lower temperature. Check the tubes connecting the faucet to the storage tank are not kinked.

Check the condition of the canister and clean or replace if necessary.

Water does not flow:

Check the shut off valve is open.

Check if supply tube is kinked.

Spare Parts

For out-of-warranty maintenance and repairs, we recommend you employ a Registered Plumber.

Before ordering spare parts, determine the correct reference number from the exploded diagram. Quote this number, and where appropriate, the color of your faucet.

 

Diagram B

WARNING: Do NOT

Push Fit Connections

Use Tools

 

 

Spout & Shank

Lever End

 

 

 

 

3-010* - LB2200 Model

10170* - LB2200 Model

 

 

 

End Cap - 10166*

3-011* - LB3200 Model

10171* - LB3200 Model

 

 

 

3-012* - LB4200 Model

10172* - LB4200 Model

 

 

 

 

 

Lever Kit - 3-002*

WARNING: Do NOT use tools

 

 

or modify

the

Push Fit

Flow Straightener

 

 

Connections

as

this could

 

 

damage the connection

10159

 

 

 

 

r e s u l t i n g i n l e a k s a n d

 

 

 

 

 

 

will void the warranty.

 

 

Cold Valve & Seat Set - 2-015

 

 

 

 

 

Hot Valve & Seat Set - 2-014

 

 

 

Cover

10167* - LB2200 Model

10168* - LB3200 Model

10169* - LB4200 Model

Spare Parts & Warranty Clamp Plate - 10115

Backnut - 92022

Limited Warranty

Congratulations on the purchase of a Franke product. Franke is one of the world’s largest manufacturers of kitchen systems. Our products are manufactured using the highest degree of technology quality and design. As a result we are proud to offer the following warranty.

Franke Inc. Kitchen Systems Division, warrants the quality of its water dispensing systems to be free from manufacturing defects for a period of five years from the date of purchase.

This warranty applies only to the original owner, providing the product has been installed in accordance with our installation instructions, used as recommended and in a normal residential application. In the event of a warranty claim, the owner will be required to provide proof of purchase. This warranty covers all components necessary to restore the product to good working condition. Franke reserves the right to inspect the installation prior to the replacement of the product or component part.

This warranty does not cover misuse or abuse, accidental damage, scuffs or scratches, abnormal usage, negligence or damage caused by improper maintenance or cleaning. Normal wear of parts is excluded from warranty. Damage caused by impurities or acts beyond our control are not covered. Any product or part which has been repaired or altered in any manner outside of Franke’s factory, unless previously authorized in writing by Franke, will void warranty. Any

replacement excludes transportation and

Mounting the Dispensing Head

The copper tubes are coiled for packing and must be carefully straightened before installation. Feed the tubes and shank through the hole in the sink ledge or counter. Assemble the clamp plate locking washer and backnut (hexagon to the top for thin sinks) fingertight. Turn the dispensing head and the spout until the handles and spout are in the required position for use and fully tighten the backnut, this will lock the spout in position.

Seasonal Shutdown

If you plan to be away from home for extended periods the following procedure must be carried out:

1

Operate the hot lever until the water runs cold.

2

Shut-off the main water supply. A stop valve was

10321 Manual background

10322 Manual backgroundManual background

Connections To

Heating Tank

*Cut to Length for Franke Canister

any labor reinstallation costs. This warranty does not allow recovery of incidental or consequential damages such as loss of use, delay, property damage or other consequential damage, and Franke accepts no liability for such damages.

The Franke warranty is limited to the above condition and to the warranty period specified herein and is exclusive. Franke DISCLAIMS all other warranties, expressed or implied, including the IMPLIED

WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR

PURPOSE. This warranty gives you specific legal rights which may vary from state to state.

What you must do: The purchaser should retain original proof of purchase. Failure to

supplied with the system for this purpose, and will be

found located on the adjacent pipe work .

3 Operate both levers to confirm that the water supply is

turned off, and to release the pressure in the system.

Silicone Tube

10306

Kit - 2-023

*Where Indicated Specify Color

do so may void this warranty.

Page 2
Image 2
Franke Consumer Products LB2200, LB4200 Installation, Care and Maintenance, Spare Parts & Warranty, Franke Little Butler