Installation

31

 

 

For each drive in the middle of the daisychain, the cable from the preceding unit connects to one of the two rows of pins (row A or row B), and the cable to the next unit connects to the other row of pins.

There are two ways to establish a drive as a master (supplying the sync reference signal to all drives connected for spindle sync).

Remove the jumper connecting the Master/Slave pins on connector J4A. The drives are shipped with the pins disconnected.

Issue that drive a Mode Select command on the SCSI interface. (The jumper must be connecting the Master/Slave pins.) The spindle sync is controlled by the RPL bits in page 4, byte 17 of the Mode Select (or Mode Sense) parameters.

Only one drive in the daisychain can be established as the master. The master drive can be located anywhere along the daisychain cable as long as both ends of the cable are terminated.