7
Section 2. Installation
The information contained in this section describes installation and initial checkout of the drive.
Site requirements
The site requirements considered are environment, airflow, space, power, grounding, and interface.
Environmental requirements
All environmental requirements for the drive are listed in Table 2 below.
Table 2. Drive environmental requirements
Conditions | Specifications |
Operating environment | Range of 5oC to 50oC (41oF to 122oF) with a |
Temperature | |
| maximum change of 20oC (36oF) per hour |
Humidity | Range of 5% to 95% relative |
| A maximum wet bulb temperature of 26oC (79oF) |
| no condensation |
Barometric pressure | |
| 104 kPa to 69 kPa (30 in Hg to 20 in Hg) |
| |
(unpacked) | Range of |
Temperature | |
| maximum change of 20oC (36oF) per hour |
Humidity | Range of 5% to 95% relative |
| A maximum wet bulb temperature of 26oC (79oF) |
| no condensation |
Barometric pressure | |
| 104 kPa to 19 kPa (30 in Hg to 6 in Hg) |
Storage/transit environment |
|
(packed) | Range of |
Temperature | |
| maximum change of 20oC (36oF) per hour |
Humidity | Range of 5% to 95% relative |
Barometric pressure | |
| 104 kPa to 19 kPa (30 in Hg to 6 in Hg) |