Draining Water Tank

When the condensate water tank is full, the “DRAIN WATER” indicator light will flash, the unit will sound several initial warning beeps, and the unit will automatically turn off.

IMPORTANT: For the indoor unit's condensate drain pump to function properly, the outdoor unit must not be more than 6 feet above indoor unit.

NOTE: If emptying water tank before “DRAIN WATER” alert, press Power On/Off "I/O" button to stop unit if it is operating.

1.Unplug power cord from outlet. Allow unit to remain off for 3-5 minutes.

2.Remove screw from from plastic mounting bracket on drain tube.

3.Remove plug from condensate tube (on back of indoor unit) and drain water into a shallow bucket. Be sure tank is completely empty.

Replace plug tightly onto end of tube.

4.Replace tube and plastic mounting bracket to original position.

5.Plug power cord into outlet. Press Power On/Off ("I/O") button.