IMPORTANT SAFETY INFORMATION
PERSONAL INJURY OR DEATH HAZARDS
ELECTRICAL HAZARDS
MECHANICAL HAZARDS
REFRIGERATION SYSTEM HAZARDS
WATER DAMAGE HAZARDS
INTRODUCTION
PROPERTY DAMAGE HAZARDS
FIRE DAMAGE HAZARDS
00001
FRIEDRICH wallmaster MODEL NUMBER CODE
SERIAL NUMBER IDENTIFICATION GUIDE
W S 08 B 1 0 B
ENERGYSTAR models
Specifications
Sleeve / Chassis Dimensions
2008 / 2009 PERFORMANCE DATA
electrical DATA
Plug/Outlet/Circuit Rating
HACR Heating Air Conditioning and Refrigeration
C. Hermetic components
FUNCTIONAL COMPONENTS
A. Mechanical components
B. Electrical components
To start unit
How to operate the Friedrich WallMaster
To adjust temperature
To adjust fan speed
To set the timer
To Activate Money Saver WY/WE models
Automatic component protection
To set the timer
Using the remote control
To adjust temperature
To adjust fan speed
Figure 5 “WS” Cooling only models
ERROR CODE MODE
TESTING THE ELECTRONIC CONTROL
ELECTRONIC CONTROL PANEL
ERROR CODES LISTING FOR “WS” MODELS
ERROR CODES LISTING FOR “WE/WY” MODELS
REBOOT THE CONTROL PANEL
Heat Pump & Electric Heat Models
SYSTEM CONTROL SWITCH - TEST
Figure 8 System Control Switch
Figure 7 System Control Panel
THERMOSTAT
COMPONENTS TESTING
ELECTRONIC CONTROL OPERATION
Heat Pump w/back up Electric Heat
Capacitor Check with Capacitor Analyzer
CAPACITORS
DEFROST THERMOSTAT
DEFROST BULB LOCATION
Drain Pan Valve
HEATING ELEMENT
DRAIN PAN VALVE
Figure 12 Heating Element
REFRIGERATION SYSTEM SEQUENCE OF OPERATION
Refrigerant Charging
SEALED REFRIGERATION SYSTEM REPAIRS
BURN HAZARD
Method Of Charging / Repairs
BURN HAZARD
FREEZE HAZARD
Overcharged Refrigerant Systems
Undercharged Refrigerant Systems
Restricted Refrigerant System
Capillary Tube Systems
HERMETIC COMPONENTS CHECK
METERING DEVICE
CHECK VALVE
ELECTRIC SHOCK HAZARD
REVERSING VALVE DESCRIPTION/OPERATION
HIGH PRESSURE HAZARD
TESTING THE COIL
CHECKING THE REVERSING VALVE
ELECTRIC SHOCK HAZARD
HIGH PRESSURE HAZARD
Procedure For Changing Reversing Valve
Touch Test in Heating/Cooling Cycle
BURN HAZARD
Locked Rotor Voltage L.R.V. Test
Single Phase Connections
Single Phase Running and L.R.A. Test
COMPRESSOR CHECKS
CHECKING COMPRESSOR EFFICIENCY
Single Phase Resistance Test
ELECTRIC SHOCK HAZARD
GROUND TEST
Recommended procedure for compressor replacement
COMPRESSOR REPLACEMENT
ELECTRIC SHOCK HAZARD
HIGH PRESSURE HAZARD
EXPLOSION HAZARD
ELECTRIC SHOCK HAZARD
ROUTINE MAINTENANCE
EXCESSIVE WEIGHT HAZARD
BLOWER WHEEL / HOUSING / CONDENSER FAN / SHROUD
ROUTINE MAINTENANCE Continued
SLEEVE / DRAIN
FRONT COVER
Possible Cause
Problem
Problem
Problem
Replace fuse, reset breaker. If repeats, check
Overload inoperative. Opens too
Sublimation
HEAT PUMP TROUBLESHOOTING
Incorrect wiring
HEAT PUMP TROUBLESHOOTING
WARMER THAN VALVE BODY
POSSIBLE CAUSES
CORRECTIONS
TEMPERATURE OF VALVE BODY
WS14B10A-E WS10B30A-D
WALLMASTER WIRING DIAGRAM ELECTRONIC CONTROL
COOL ONLY MODELS
WS08B10A-D,A-F WS10BIOA-D WS14B10A-D
COOL WITH ELECTRIC HEAT MODELS
WE10B33C-A WE13B33C-A WE16B33C-A
WALLMASTER WIRING DIAGRAM ELECTRONIC CONTROL
HEAT PUMP WITH ELECTRIC HEAT MODELS
WY10B33C-A WY13B33C-A
WALLMASTER WIRING DIAGRAM ELECTRONIC CONTROL
COOL WITH ELECTRIC HEAT MODELS
WALLMASTER WIRING DIAGRAM
ELECTROMECHANICAL CONTROL
WE10B33A-C WE13B33B-D,B-E WE16B33A-C,A-D
HEAT PUMP WITH ELECTRIC HEAT MODELS
WY10B33A-C,A-D WY13B33A-C,A-D
WALLMASTER WIRING DIAGRAM
ELECTROMECHANICAL CONTROL
SB / Sub Base
Installation Accessories
Exterior Grilles
DK / Drain Kit
MOUNTING HARDWARE PROVIDED
WALL PREPARATION
INSTALLATION INSTRUCTIONS FOR “WSC” SLEEVE
STEP STEP 3 STEP
INSTALLATION REQUIREMENTS
SLEEVE INSTALLATION
MECHANICALCUT/SEVER HAHAZARD CUT/SEVER
MECHANICALCUT/SEVER HAZARD
FIGURE B
SEALING GASKET INSTALLATION INSTRUCTIONS
SIDE PROFILE OF WALL SLEEVE
FIGURE A
MECHANICAL HAZARD MECHANICALCUT/SEVER HAZARD
MECHANICALCUT/SEVER HAZARD
EXCESSIVE WEIGHT HAZARD
MECHANICALCUT/SEVER HAZARD
MECHANICALCUT/SEVER HAZARD
MECHANICALCUT/SEVER HAZARD
WALLMASTER→ THRU-THE-WALLAIR CONDITIONERS
FIRST YEAR
SECOND THROUGH FIFTH YEAR
LIMITED WARRANTY
Page
4200 N. Pan Am Expressway · San Antonio, Texas
TECHNICAL SUPPORT CONTACT INFORMATION
FRIEDRICH AIR CONDITIONING CO
Post Office Box 1540 · San Antonio, Texas
Post Office Box 1540 · San Antonio, Texas
FRIEDRICH AIR CONDITIONING CO