STEP 6 - Place the mounting pad.

Position the mounting pad so that the mounting holes are away from the house. Set the outdoor module on the mounting pad so that the module feet align with the mounting holes. Screw the outdoor module to the mounting pad with the 4 condenser pad installation washers and screws provided (Items #7 and #8 in the Accessories List).

STEP 6

STEP 7 – Connect the quick connector from the indoor line set outdoor module.

1.Open lock handle on line- set connector by pulling back and rotating toward indoor unit.

2.Grasp outer lock collar on line-set connector and pull back until it stops.

3.While holding outer lock collar rearward, push line- set connector body over base connector on outdoor unit half way and release outer lock collar.

4.Continue to push line-set connector onto base con- nector until outer lock col- lar engages base connector. The outer lock collar will snap into position with base connector and a click will be heard.

5. Grasp lock handle and

 

6. Install security screw

 

 

 

 

 

rotate to its closed posi-

 

(Item 12 in the Accessories

 

 

tion.

 

List) to prevent tampering

 

1.

 

 

 

 

 

 

with line-set connector

 

 

 

 

 

 

 

mechanism.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you have excess connecting line, roll the line into a coil approximately 2 feet wide, secure with the provided wire ties and store between the outdoor module and the wall. DO NOT cut or kink the connecting line!

STEP 8 – Connect the electrical connector from the connecting

2.

 

line to outdoor module

 

1.Connect the black colored electrical connector from the connecting line into the mat- ing connector on the outdoor module. The connectors will snap into place with a click. (The plug can be removed by pushing in the side tabs on the plug and pulling the plug body down and out of the receptacle.)

2.Install the electrical cord retention bracket (Item #5 in the Accessories List) using two

#8 x 3/4” screws (Item #9 in the Accessories List). The opening in the electrical cord Item #5

retention bracket should fit over the cord. Do not pinch the cord in the bracket.

Item #9

 

3.Install the plastic cover (Item #2 in the Accessories List) as shown. There are two screws on the outer flange of the cover and one screw under the electrical connec- tor access cover. Once secure, use enclosed screw (Item #9 in the Accessories List) to close the access door.

All Covers must be in place to operate unit.

Item #9

 

SHOCK HAZARD exists without electrical access cover.

 

Cover cannot be installed without completing steps 8.1 through 8.3 properly.

 

3.

Page 6
Image 6
Friedrich BRO412W1A installation instructions Place the mounting pad

BRO412W1A specifications

The Friedrich BRO412W1A is a state-of-the-art portable air conditioning unit that combines powerful cooling capabilities with energy efficiency, making it a popular choice for residential and commercial use. Its sleek design is complemented by a variety of features and technologies that enhance user comfort and convenience.

One of the main features of the BRO412W1A is its cooling capacity. With a rating of up to 12,000 BTUs, this unit is capable of cooling spaces of up to 550 square feet. This makes it ideal for bedrooms, living rooms, offices, and other medium-sized areas. Additionally, its dehumidifying capability helps reduce humidity levels, creating a more comfortable environment, especially during hot and humid summer months.

The portable nature of the BRO412W1A offers significant advantages. It comes equipped with caster wheels, allowing users to move it from room to room with ease. This mobility means that users can have control over which areas they want to cool at any given time, providing flexibility that fixed units often lack.

In terms of energy efficiency, the BRO412W1A features an Energy Efficiency Ratio (EER) that ensures that it consumes minimal power while delivering optimal performance. This not only reduces electricity bills but also makes it an environmentally friendly choice. The unit is compliant with the latest energy efficiency standards, further ensuring that it operates with a low carbon footprint.

The self-evaporative technology in this air conditioner contributes to its efficiency by using the condensation produced during the cooling process. Rather than needing frequent manual drainage, the unit can recycle this condensation, leading to less hassle for the user.

For user convenience, the BRO412W1A includes a remote control, allowing you to adjust settings from anywhere in the room. The digital display and programmable timer facilitate easy operation, while multiple fan speeds and modes, including a cooling mode and fan-only mode, enable users to customize their comfort levels.

Overall, the Friedrich BRO412W1A stands out as an advanced portable air conditioning solution, offering robust features and technologies that prioritize both user comfort and efficiency. Whether for home or office use, it efficiently addresses the need for effective cooling in an increasingly warm climate.