Disassembly
3 CAPACITOR |
|
| |
Remove the control box |
|
| |
Remove the screw which fasten control panel from |
|
| |
control box |
|
| |
Remove the screw which located in the front |
|
| |
Open the bottom side of control box |
|
| |
Remove the screw and the clamp which fastens |
|
| |
the capacitor |
|
| |
Disconnect all the leads of capacitor terminals |
|
| |
Re install the components by referring to the | Figur | 10 | |
removal procedure, above (See Figure 10) | |||
|
|
4POWER CORD
1Remove the control box
2Open the control box
3Disconnect the grounding screw from the control box
4 | Disconnect the 2 receptacles |
|
|
5 | Remove a screw which fastens the clip cord |
| |
| (See Figure 11) |
|
|
6 | Remove the power cord |
|
|
7 | Re install the component by referring to the above |
| |
| removal procedure, above |
|
|
| (Use only one ground marked hole | for ground |
|
| connection |
| Figure 11 |
8 | the supply cord of this appliance is damaged, | ||
| must be replaced by the special cord | (The |
|
| special cord means the cord which has the same |
| |
| specification marked on the supply cord attached at |
| |
| the unit |
|
|
Refrigerating Cycle
CAUTION: Discharge the refrigerant system using a Freon TM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO
1.CONDENSER
1.Remove the cabinet.
2.Remove the 3 screws which fasten the
brace.
3. Remove the 3 screws which fasten the condenser and shroud.
4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
5. Remove the condenser carefully.
6.
Figure 12
12
Room Air Conditioner