Friedrich CP06F10, CP08F10 manual Troubleshooting Guide, Romote controller does not operate

Models: CP08F10 CP06F10

1 29
Download 29 pages 4.83 Kb
Page 22
Image 22
• Romote controller does not operate.

Troubleshooting Guide

Possible Trouble 5

• Romote controller does not operate.

Is the voltage of Battery

NO

 

• Exchange the battery.

about over 2.3V?

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

Is the voltage No.16

of CN-DISP1 on Main P.W.B

Ass'y DC 5V?

YES

Is the connection of

CN-DISP1 all right?

YES

• Exchange Receiver Ass'y. Manual backgroundManual background

Possible Trouble 6

NO

Manual background • Check the P.W.B pattern.

NO

 

• Connect connector to

 

 

 

 

 

 

CN-DISP1 exactly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• It displays abnormally on Display P.W.B Ass'y.

Is the IC01G all right?

YES

NO

Is the connection of

CN-DISP1 all right?

YES

Does the Q01G,

Q02G, Q03G Q04G operate normally

on main P.W.B Ass'y?

YES

Exchange the display P.W.B Ass'y.

NO

NO

NO

Manual background • Exchange IC01G.

• Connect connector Manual background to CN-DISP1 exactly.

Manual background • Exchange Q01G, Q02G, Q03G, Q04G