Electrical Requirements

 

Window opening measurements:

27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).

20" min. (50.8 cm) opening height (B).

 

A

 

 

B

A .27"

min. (76

. 2 c m)

B . 20" min. (50

. 8 c m)

Through-the-wall installation

The wall opening measurements should be:

Height (A): 17 ¼" plus twice thickness of wood used to build frame

Width (B): 26 ¼"

Depth (D): 4" minimum to 8" maximum.

 

C

 

A

 

B

 

D

 

C

A. 17 ¼"

C. Wood thickness

B. 26 ¼"

D. 4" minimum to

 

8" maximum.

Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the model and serial number (nameplate) label. The model and serial number label is located behind the front panel on the flange below the control panel area.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply

 

 

cord

Wiring requirements

 

 

CP15

115-volt (103.5 min. - 126.5 max.)

 

0-12 amps

 

15-amp time-delay fuse or circuit breaker

 

Use on single outlet circuit only.

 

 

CP18 / CP24

230-volt (207 min. - 253 max.)

¹⁄₄"

 

0-12 amps

(0.6 cm)

15-amp time-delay fuse or circuit breaker Use on single outlet circuit only.

4

Page 6
Image 6
Friedrich CP15F10 manual Through-the-wallinstallation, Window installation, Electrical Requirements