Recommended grounding method

Recommended grounding method

This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local cod es and ordinances. If a mating outlet is not available, it is the customer' s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical component installer.

It is the customer' s responsibility:

To contact a qualified electrical installer, and

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 - latest edition, and all local cod es and ordinances.

Copies of the standards listed may be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

Power Supply Cord

NOTE: Your unit’s device may differ from the ones shown.

B A

TEST

RESET

TEST

RESET

BA

A.Reset button

B.Test button

This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-t he-art electronics that sense leakage current. If the cord is crushed, the electronics detect leakage current and pow er will be disconnected in a fraction of a second.

To test your power supply cord:

1.Plug power supply cord into a grounded 3 prong outlet.

2.Press RESET.

3.Press TEST (listen for click; Reset button will trip and pop out).

4.Press and release RESET (listen for click; Reset button will latch and remain in). The power supply cord is ready for operation.

NOTES:

The Reset button must be pushed in for proper operation.

The power supply cord must be replaced if it fails to trip when the test button is pressed or if it fails to reset.

Do not use the power supply cord as an off/on switch. The power supply cord is designed as a protective device.

A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.