Window installation
Window opening measurements:
30"min. to 40" max. (76.2 cm to 101.6 cm) opening width. 20" min. (50.8 cm) opening height.
A |
B |
A. 30" min. (76.2 cm)
B . 20" min. (50.8 cm)
Through-the-wall installation
The wall opening measurements should be:
Width: 30" (76.2 cm) plus twice thickness of wood used to build frame.
Height: 19ı3/�4ˇ" (50.2 cm) plus twice thickness of wood used to build frame.
Depth: 2�1/�2ˇ" (6.4 cm) minimum to 8" (20.3 cm) maximum.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet. Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located behind the front panel on the flange below the control panel area.
Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.
Power supply |
|
cord | Wiring requirements |
C
1��/2"
A
B
D
| C |
A. 19 �3/4�" (50� .2 cm) | C. Wood thickness |
B. 26�1/2�" (66.1 cm) | D. 2�1/2�" (6.4 cm) minimum to |
| 8" (20.3 cm) maximum |
(0.6 cm) |
Use on single outlet circuit only.
4