ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.

Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.

Vertical Air Direction Adjustment

Press the SET button (Fig. 5 O).

Each time the button is pressed, the air direction range will change as follows:

RDANGER!

Never place fingers or foreign objects in- side the outlet ports, since the internal fan operates at high speed and could cause personal injury.

1 2 3 4 5 6 7

Types of Air flow Direction Setting:

1,2,3 : During Cooling/Dry modes

4,5,6,7 : During Heating mode

The Remote Control Unit’s display does

 

not change.

1

 

2

 

3

4

5

6

7

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry mode : Horizontal flow 1

During Heating mode

: Downward flow 7

During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this pe- riod.

Always use the Remote Control Unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper op- eration; in this case, stop operation and restart. The louvers should begin to operate properly again.

During use of the Cooling and Dry modes, do not set the Air Flow Direc- tion Louvers in the Heating range (4 - 7) for long periods of time, since wa- ter vapor may condense near the out- let louvers and drops of water may drip from the air conditioner. During the Cooling and Dry modes, if the Air Flow Direction Louvers are left in the heat- ing range for more than 30 minutes, they will automatically return to posi- tion 3.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air flow in the direction you prefer.

Right-Left Louvers

RDANGER!

When adjusting the Right-Left Louvers, it is necessary to stop the Air-Conditioner first and make sure that it stops completely before adjusting the direction.

knob

knob(three places)

En-9

Page 12
Image 12
Friedrich MW18Y3FM Adjusting the Direction of AIR Circulation, Vertical Air Direction Adjustment Press the SET button O

MW09Y3FM, MW12Y3FM, MW18Y3FM, MR24DY3F, MR36TQY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM specifications

Friedrich is recognized for producing high-performance and reliable air conditioning units, and the models MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F exemplify their commitment to quality.

The MW series, particularly the MW12Y3FM, MW09Y3FM, and MW18Y3FM, offers versatile cooling options suitable for different room sizes. These units come equipped with energy-efficient inverter technology, which adjusts the compressor speed to maintain desired temperatures while reducing energy consumption. This not only helps save on electricity bills but also enhances comfort by minimizing temperature fluctuations.

One of the standout features of these models is their user-friendly Wi-Fi capability, enabling remote control from smartphones and smart home systems. This technology simplifies operation, allowing users to adjust settings, monitor usage, and schedule operations from anywhere. Furthermore, these models include programmable timers and multiple fan settings, providing enhanced flexibility and control over indoor climates.

The MR24DY3F and MR36TQY3F models cater to larger spaces, making them ideal for commercial applications or open-plan areas. Both units feature powerful cooling capacities and are designed to efficiently circulate cool air even in high-demand scenarios. They are also equipped with advanced filtration systems that enhance indoor air quality by capturing dust, allergens, and other particulates.

In terms of durability, Friedrich air conditioners are constructed with high-quality materials, ensuring longevity and resistance to wear and tear. The MW series also indicates quiet operation, with noise-reducing technologies that allow for peaceful environments, whether in homes or workplaces.

Additional characteristics include precise temperature control, an eco-friendly refrigerant, and the ability to run in a dehumidification mode, which is particularly valuable during humid months. The sleek design of these units makes them aesthetically pleasing, allowing them to blend seamlessly into any environment without compromising functionality.

Overall, Friedrich's MW12Y3FM, MW09Y3FM, MW18Y3FM, MR24DY3F, and MR36TQY3F models represent a blend of innovative technology, efficiency, and performance, making them ideal choices for anyone seeking reliable climate control solutions.