Condensation Handling

Condensation Handling

Draining Water

Your ZoneAire® Portable Air Conditioner is designed to evapo- rate the condensation removed from the interior space through the exhaust hose. Under certain conditions it is possible that the unit will not evaporate 100% of the removed moisture.

The unit is designed with a built-in reservoir and pump to ac- cumulate excess condensate and help dispose of it.

Internal Water Level

1.Under any mode if the water level is in the “low” area the unit will function normally.

2.If the water level is in the “normal” area the unit will continue to function normally with the internal recirculation pump run- ning to evaporate the water. You may hear the pump run at times.

3.If the water level is in the “high” area the unit will function normally and the water pump will work for 10 minutes. After that, if the water level returns to the “low” or “normal” level the unit will function normally. If after running 10 minutes, the water level is still in the “high” area the machine will turn off and the WATER FULL lamp on the control panel will il- luminate. The LCD window indicates failure code E5.

The water can be drained from the unit either by removing the base stopper and letting the water drain by gravity. Or the con- densate pump hose may be used to direct the condensate to a drain location like a sink.

1.When the WATER FULL lamp is on unplug the unit and move the unit to a suitable location for draining the conden- sation.

2.If using the gravity drain method ensure that the base stop- per is located above a suitable area for draining the conden- sate and remove the stopper. Re-install the stopper once all water has drained.

If using the condensate removal pump ensure that the conden- sate pump hose is located in a proper area for drainage. Re- store power to the unit and press both the TIMER and SWING buttons simultaneously and the pump will begin to run.

3.Return the unit to the original location and restore power and duct connections.

4.The WATER FULL indicator should be off and the unit will return to normal operating mode.

water tank

water

Maintenance /Service

!WARNING

Disconnect the power before cleaning.

Make sure there is no power to the unit before beginning to maintain or repair the unit in or- der to prevent accidents caused by electrical shock.

Cleaning the air filter

If the air filter is blocked with a lot of dust, the air flow volume will be reduced. Clean the filter once every two weeks.

Open and clean the air filter:

1.Pull the filter out as shown in the drawing.

2.Take out the air filter from the filter cover.

3.Wash the air filter by immersing it gently into warm (about 40°C or 104°F) water with a neutral detergent or vacuum the filter clean.

4.Rinse the filter and dry it thoroughly in a shaded place.

5.Install the air filter back to its original place.

7