Troubleshooting
Self diagnosis function
The following error codes are
Failure code | Diagnosis of Malfunction |
E2 | Room Temperature sensor failure |
E3 | Coils sensor failure |
E4 | Unit malfunction |
E5 | Water level exceeded capacity |
Installation
Selection of installation location
Put the portable air conditioner in a flat location where the air outlets cannot be covered up, place the unit no less than 20 in. (50 cm) away from a wall or other obstacle.
18 | inch | 22 | inch |
| |||
|
| ||
|
|
|
Mounting the intake and exhaust hoses
1)Fit one end of the exhaust hose to the exhaust terminal of the unit then rotate it 2 - 3 revolutions to tighten the hose into the terminal.
2)Put the other end (discharge) to the nearest window.
3)Install the intake hose in the same manner
Note: The length of the air intake and exhaust hoses are be- tween 24" - 72". Try to keep the hose as straight and horizontal as possible.
Air exhaust terminal |
Air |
intake |
terminal |
Air intake hose |
Instructions to install hose
If the hose becomes disconnected from the hose fitting it must be reinserted. Fit the hose to the hose fitting then rotate it
Correct mounting shown below
(If mounting in the wall, the height of the hole should be 16" - 51")