Friedrich CP18 Thru-The-Wallair Conditioners, Specifications, R-410A,            

Models: CP08 CP24 CP18 CP15 CP06 Room Air Conditioners

1 28
Download 28 pages 12.45 Kb
Page 21
Image 21


THRU-THE-WALL AIR CONDITIONERS

SPECIFICATIONS

 

 

Energy Star® models

Estar

 

 

 

 

 

 

 

 

Energy

Estimated

 

Room

 

 

 

 

 

 

 

 

 

 

Efficiency

Yearly

Moisture

Side Air

 

Net

 

Cooling

Heating

Volts

Cooling

Cooling

Heating

Heating

Ratio

Operating

Removal

Circulation

 

Weight

Model

Capacity Btu

Capacity Btu

Rated

Amps

Watts

Amps

Watts

EER

Cost

Pints/HR

CFM

Sleeve

Lbs

 

 

 

 

 

 

 

 

 

 

 

 

 

WALLMASTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool only

 

 

 

 

 

 

 

 

 

 

 

 

 

WS08C10

7800

NA

115

7.1

788

-

-

9.9

1.2

250

WSD

93

WS10C10

9700

NA

115

10.0

1032

-

-

9.4

$82

2.4

257

WSD

103

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS12C10

11900

NA

115

11.8

1266

-

-

9.4

$101

3.3

295

WSD

112

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS10C30

9500/9200

NA

230/208

4.5/4.7

989/958

-

-

9.6/9.6

$79

1.5

300

WSD

101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS13C30

12600/12300

NA

230/208

6.3/6.7

1340/1309

-

-

9.4/9.4

$107

3.6

290

WSD

109

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS15C30

14500/14500

NA

230/208

8.3/8.2

1706/1706

-

-

8.5/8.5

$136

4.2

290

WSD

119

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

WY09C33

9300/9000

7300/7300

230/208

4.4/4.7

989/957

3.8/4.0

839/793

9.4/9.4

$79

2.1

250

WSD

103

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WY12C33

12000/11800

9350/9200

230/208

6.1/6.4

1395/1372

4.8/5.1

1062/1010

8.6/8.6

$111

2.6

275

WSD

111

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool with Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

WE10C33

9500/9200

11000/9100

230/208

4.5/4.7

989/958

16.0/14.7

3550/2950

9.6/9.6

$79

1.5

300

WSD

121

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE13C33

12600/12300

11000/9100

230/208

6.3/6.7

1340/1309

16.0/14.7

3550/2950

9.4/9.4

$107

3.6

290

WSD

107

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE15C33

14500/14500

11000/9100

230/208

8.3/8.8

1706/1706

16.0/14.7

3550/2950

8.5/8.5

$136

4.2

290

WSD

116

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNI-FIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool Only

 

 

 

 

 

 

 

 

 

 

 

 

 

US08C10

8000

-

115

7.5

830

-

-

9.6

$66

2.2

260

USC

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US10C10

9800

-

115

9.6

1040

-

-

9.4

$83

3.2

285

USC

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US12C10

11500

-

115

11.2

1220

-

-

9.4

$97

3.8

290

USC

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US10C30

10000/9800

-

230/208

4.7/5.2

1060/1040

-

-

9.4/9.4

$85

3.2

285

USC

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US12C30

11500/11200

-

230/208

5.6/6.0

1220/1190

-

-

9.4/9.4

$97

3.8

290

USC

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US14C30

13000/12600

-

230/208

7.0/7.5

1530/1480

-

-

9.4/9.4

$122

4.0

310

USC

87

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool with Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

UE08C13

8000

3850

115

7.5

830

10.7

1230

9.6

$66

2.2

260

USC

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UE10C33

10000/9800

11200/9200

230/208

4.7/5.2

1060/1040

15.3/14.0

3500/2900

9.4/9.4

$85

3.2

285

USC

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UE12C33

11500/11200

11200/9200

230/208

5.6/6.0

1220/1190

15.3/14.0

3500/2900

9.4/9.4

$97

3.8

290

USC

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.

WALLMASTER HEAT PUMP

HEATING PERFORMANCE: Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35°F.

Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating perfor- mance will be satisfactory.

Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.

DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode.

DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.

Plug Face/ Circuit Rating

 

 

Circuit Rating

 

 

Wall

WallMaster

Uni-Fit

Breaker

Plug Face

Power Cord

Outlet

Model Number

Model Number

or T-D Fuse

(NEMA#)

Length (ft.)

Appearance

 

 

 

 

 

 

 

 

 

 

 

 

WS08C10, WS10C10,

US08C10, UE08C13

125V - 15A

5 - 15P

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS12C10

US10C10, US12C10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS10C30, WS13C30,

US10C30, US12C30,

250V - 15A

6 - 15P

4

 

 

 

 

 

 

 

WS15C30

US14C30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE10C33, WE13C33,

UE10C33, UE12C33

250V - 20A

6 - 20P

4

 

 

 

 

 

 

 

WE15C33, WY09C33, WY12C33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.

Due to continuing research in new energy-saving technology, specifications are subject to change without notice. As an Energy Star® partner, Friedrich Air Conditioning Co. has determined that the selected Energy Star® models meet the Energy Star® guidelines for energy efficiency.

Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.

† The estimated yearly operating cost of this model was not available at the time the range was published.

R-410A

All models use

environmentally friendly R-410A refrigerant.

LISTED

PORTABLE AIR CONDITIONERS

21

Page 21
Image 21
Friedrich CP18 Thru-The-Wallair Conditioners, Specifications, R-410A,            , Model, Cool only, Heat Pump