Friedrich UE12C33 manual Power Cord, Thermostat, 12Room Air Conditioner, Disassembly Instructions

Models: UE08C13 UE10C33 UE12C33

1 30
Download 30 pages 35.35 Kb
Page 12
Image 12
10. POWER CORD

Disassembly Instructions

10. POWER CORD

1.Remove the control box. (Refer to section 3)

2.Unfold the control box. (Refer to section 9)

3.Disconnect the grounding screw from the control box.

4.Disconnect 2 receptacles.

5.Remove a screw which fastens the clip cord.

6.Pull the power cord. (See Fig. 13)

7.Re-install the component by referring to the

removal procedure, above.

(Use only one ground-marked hole 11. THERMOSTAT for ground connection.)

8.If the supply cord of this appliance is damaged, it must be replaced by the special cord.

(The special cord means the cord which has the same specification marked on the supply cord fit- ted to the unit.)

Cool

 

 

Energy

 

 

Saver

 

 

Fan

 

F1

 

 

F3F2MLOWED

 

Timer

HIGH

MODE

'F

TIMER

TEMP

 

FAN

 

 

 

 

SPEED

 

 

POWER

FIG. 13

11. THERMOSTAT

1.Remove the control box. (Refer to section 3)

2.Unfold the control box. (Refer to section 9)

3.Disconnect the theristor terminals from main P.W.B assembly.

4.Remove the thermostat. (See Fig. 14)

5.Re-install the components by referring to the removal procedure, above.

Cool

 

 

Energy

 

 

Saver

 

 

Fan

 

F1

 

 

F2LOW

 

 

F3 MED

 

Timer

HIGH

 

'F

 

 

TEMP

 

 

FAN

 

 

SPEED

 

 

POWER

FIG. 14

12Room Air Conditioner

Page 12
Image 12
Friedrich UE12C33, UE10C33, UE08C13 manual Power Cord, Thermostat, 12Room Air Conditioner, Disassembly Instructions