ROUTINE MAINTENANCE

NOTE: Units are to be inspected and serviced by qualified service personnel only.

Routine maintenance is required annually or semi-annually, depending upon annual usage.

1.Clean the unit air intake filter at least every 250 to 300 fan hours of operation or when the unit’s indicator light is on if so equipped. Clean the filters with a mild detergent in warm water and allow to dry thoroughly before reinstalling.

2.The indoor coil (evaporator coil), the outdoor coil (condenser coil) and base pan should be inspected periodically (yearly or bi-yearly) and cleaned of all debris (lint, dirt, leaves, paper, etc.). Clean the coils and base pan with a soft brush and compressed air or vacuum. If using a pressure washer, be careful not to bend the aluminium fin pack. Use a sweeping up and down motion in the direction of the vertical aluminum fin pack when pressure cleaning coils. Cover all electrical components to protect them from water or spray. Allow the unit to dry thoroughly before reinstalling it in the sleeve.

NOTE: Do not use a caustic coil cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser.

Inspect the indoor blower housing, evaporator blade, condenser fan blade, and condenser shroud periodically (yearly or bi-yearly) and clean of all debris (lint, dirt, mold, fungus, etc.) Clean the blower housing area and blower wheel with an antibacterial / antifungal cleaner. Use a biodegradable cleaning agent and degreaser on condenser fan and condenser shroud. Use warm or cold water when rinsing these items. Allow all items to dry thoroughly before reinstalling them.

3.Periodically (at least yearly or bi-yearly): inspect all control components, both electrical and mechanical, as well as the power supply. Use proper testing instruments (voltmeter, ohmmeter, ammeter, wattmeter, etc.) to perform electrical tests. Use an air conditioning or refrigeration thermometer to check room, outdoor and coil operating temperatures. Use a sling psychrometer to measure wet bulb temperatures indoors and outdoors.

4.Inspect the surrounding area (inside and outside) to ensure that the units’ clearances have not been compromised or altered.

5.Inspect the sleeve and drain system periodically (at least yearly or bi-yearly) and clean of all obstructions and debris. Clean both areas with an antibacterial and antifungal cleaner. Rinse both items thoroughly with water and ensure that the drain outlets are operating correctly. Check the sealant around the sleeve and reseal areas as needed.

6.Clean the front cover when needed. Use a mild detergent. Wash and rinse with warm water. Allow it to dry thoroughly before reinstalling it in the chassis.

4

Page 4
Image 4
Friedrich WS14B10A-C, WS08B10A-C, WE16B33A-B, WE13B33B-B, WE10B33A-B, WY13B33A-B, WY10B33A-B, WS13B30B-C Routine Maintenance

WS10B10A-C, WS10B30A-C, WS16B30A-C, WS13B30B-C, WY10B33A-B specifications

Friedrich manufactures a range of high-quality air conditioning units, including models WY13B33A-B, WS13B30B-C, WE16B33A-B, WS10B10A-C, and WS08B10A-C. These units are designed to offer reliable climate control for both residential and commercial spaces, while incorporating advanced technologies and energy-efficient features.

The WY13B33A-B model stands out with its impressive cooling capacity of 13,000 BTU, making it ideal for medium-sized rooms. It employs inverter technology, which not only optimizes energy consumption but also ensures a quieter operation by adjusting the compressor speed based on cooling demand. This model is equipped with a programmable thermostat, allowing users to set preferred temperatures and schedules, enhancing both comfort and efficiency.

The WS13B30B-C also features a robust cooling capability, paired with a sleek design that fits seamlessly into various interiors. Its user-friendly digital control panel and remote control operation enhance the overall user experience. Additionally, the unit is designed with energy-saving modes that further contribute to lower electricity bills without sacrificing performance.

The WE16B33A-B model is tailored for larger spaces, boasting a cooling capacity of 16,000 BTU. This makes it a great choice for open-plan areas or rooms with high ceilings. Its multi-speed fan and adjustable louvers provide customized airflow, ensuring that every corner of the room is adequately cooled. Notably, this model includes a dehumidification function that efficiently reduces humidity levels, promoting a more comfortable environment.

On the other hand, the WS10B10A-C and WS08B10A-C models are compact, making them perfect for smaller areas or specific applications such as bedrooms or home offices. Both units have a cooling capacity of 10,000 BTU and 8,000 BTU, respectively. They feature easy-to-use mechanical controls and are designed for simple installation, making them an excellent choice for individuals seeking an affordable yet effective cooling solution.

All Friedrich air conditioning units are built with durability and longevity in mind, incorporating high-quality materials and construction practices. Additionally, they boast reliable warranty options, ensuring peace of mind for consumers. In summary, Friedrich’s WY13B33A-B, WS13B30B-C, WE16B33A-B, WS10B10A-C, and WS08B10A-C models represent a blend of innovative technology, energy efficiency, and performance, tailored to meet diverse cooling needs.