Solutions To Common Problems | 39 |
Ice Dispenser
Problem | Cause | Correction |
Dispenser will not | • Water supply is not connected. |
dispense ice. | • Ice storage container is empty. |
|
•Connect water supply (see page 9).
•When the first supply of ice is dropped into the container, the dispenser should operate.
•Freezer temperature is set too warm.
•Household water line valve is not open.
•Turn freezer control to a higher setting so that ice cubes will be made. When first supply of ice is made, dispenser should operate.
•Open household water line valve. Allow sufficient time for the ice to be made. When ice is made, the dispenser should operate.
•Freezer door is not closed.
•Ice dispensing arm has been held in for more than
•Ensure freezer door is closed.
•Motor is overloaded. Motor overload protector will reset in approximately 3 minutes. Ice can then be dispensed.
Ice dispenser is | • Ice has melted and frozen around |
jammed. | auger due to infrequent use, |
| temperature fluctuations, and/or |
| power outages. |
•Remove ice container, thaw, and empty the contents. Clean container, wipe dry, and replace in proper position. When new ice is made, dispenser should operate.
•Ice cubes are jammed between ice maker and back of ice container.
•Ice cubes are frozen together.
•Ice cubes are hollow or smaller than normal.
•Remove ice cubes that are jamming the dispenser.
•Use the dispenser often so that cubes do not freeze together.
•The ice & water filter cartridge could be clogged. Replace the filter cartridge. Dispensing system operates best at 20- 100 psi water pressure. Well water pressures should fall within this range.
Water Dispenser
Problem | Cause | Correction |
Dispenser will not | • Water supply is not connected. |
dispense water. | • Household water line valve is not |
| open. |
| • Freezer door is not closed. |
| • Ice & water filter cartridge is clogged. |
| • Front filter not fully installed, if |
| equipped |
|
|
Water has an odd | • Water has been in the tank for a |
taste and/or odor. | period of time. |
| • Unit not properly connected to cold |
| water line. |
| • Tubing used in the household water |
| supply and installation may affect |
| water taste and odor. |
| • Water has a high mineral content. |
|
|
Water pressure is | • |
extremely low. | low (well systems only). |
| • Reverse osmosis system is in |
| regenerative phase. |
•Connect water supply (see page 9).
•Open household water line valve. See Problem section Ice Maker Is Not Making Ice.
•Ensure that freezer door is closed.
•Replace filter cartridge.
•Push filter in until you hear a “click”. Filter should be flush with cabinet.
•Draw and discard
•Connect unit to cold water line that supplies water to the kitchen faucet.
•For best results, use copper tubing for water connections.
•Contact water treatment plant for help.
•Have someone turn up the
•It is normal for a reverse osmosis system to be below 20 psi during the regenerative phase.
241540100_eb_sxs_Use&Care_En.pmd | 39 | 1/22/2004, 10:34 AM |