induction COOKTOP INSTALLATION INSTRUCTIONS
Important Notes to the Installer
1.Read all instructions contained in these installation instructions before installing the cooktop.
2.Remove all packing material before connecting the electrical supply to the cooktop.
3.Observe all governing codes and ordinances.
4.Be sure to leave these instructions with the consumer.
5.Only certain cooktop models may be installed over certain
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for future reference.
IMPORTANT SAFETY INSTRUCTIONS
•Be sure your cooktop is installed and grounded properly by a qualified installer or service technician.
•This cooktop must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.
WARninG The electrical power to the cooktop must be shut off while line connections are being made. Failure to do so could result in serious injury or death.
Provide Electrical Connection
Install the junction box under the cabinet and run 120/240 or 120/208 Volt, AC wire from the main circuit panel. NOTE: DO NOT connect the wire to the circuit panel at this time.
Electrical Requirements
Observe all governing codes and local ordinances.
1.A
2.A circuit breaker or fuse rated at 40 Amp is recommended for the 30" model and a circuit breaker or fuse at 50 Amp is recommended for the 36" model.
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI/NFPA No.
WARninG An extension cord must not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury.
3.The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable.
The flexible armored cable extending from this appliance should be connected directly to the grounded junction box. The junction box should be located as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.
4.A suitable strain relief must be provided to attach the flexible armored cable to the junction box.
Unpacking Instructions
1.Unpack and visually inspect the cooktop.
2.Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily. It is important that the
Electrical Connection
Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable strain relief at the point the armored cable enters the junction box. Then make the electrical connection as follows.
Electrical ground is required on this appliance.
This appliance is equipped with a copper conductor flexible cable. If connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances. Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire. Follow the connector manufacturer recommended procedure closely.
This appliance is manufactured with a supply wire and a frame connected green or bare copper grounding wire.
DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.
3