If the cable from appliance is equipped with 3 wires:

induction COOKTOP INSTALLATION INSTRUCTIONS

If the cable from appliance is equipped with 3 wires:

Where local codes permit connecting the appliance-grounding conductor to the neutral (white) wire (see figure 3):

1.Disconnect the power supply.

2.In the circuit breaker, fuse box or junction box, connect appliance and power supply cable wires as shown in figure 3.

Manual background You may not ground the cooktop through the neutral (white) wire if cooktop is used in a new branch circuit installation (1996 NEC),

If cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes do not permit grounding to the neutral (white) wire (see figure 4):

1.Disconnect the power supply.

2.In the circuit breaker, fuse box or junction box, connect appliance and power supply cable wires as shown in figure 4.

Cable from Power Supply

mobile home, recreational vehicle, or where local codes do not permit grounding to the neutral

Ground Wire

White Wire

(white) wire.

Cable from Power Supply

White Wire (Neutral)

Red

WiresBlack Wires

 

Junction Box

 

U.L.-Listed

Green Wire (Ground)

Conduit Connector

Cable from

 

appliance

 

Figure 3 - 3-WIRE GROUNDED JUNCTION BOX

When grounding to the neutral (white) wire is prohibited, you must use a 4-wire power supply cable. See Figure 4. Failure to heed this warning may result in electrocution or other serious personal injury.

Red

WiresManual background Black

Wires

 

Junction

 

Box

Green Wire (Ground)

U.L.-Listed Conduit

 

Connector

Cable from appliance

Figure 4 - 4-WIRE GROUNDED JUNCTION BOX

Manual backgroundWARninG If connecting to a 4-wire power supply cable electrical system, the appliance frame connected ground wire MUST NOT be connected to the neutral wire of the 4-wire electrical system.

NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-listed for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor wire is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.

4

Page 4
Image 4
Frigidaire 318205412 induction COOKTOP INSTALLATION INSTRUCTIONS, If the cable from appliance is equipped with 3 wires