Frigidaire FGEW2745K F/W/B dimensions Gas Cooktop Installation Over

Models: FGEW2745K F/W/B

1 9
Download 9 pages 63.64 Kb
Page 4
Image 4
Gas Cooktop Installation Over

Gas Cooktop Installation Over 30"/27" Electric Single Wall Oven

30"/ 27" Electric Single Wall Oven Under-Counter Installation Specifications

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line.

For detailed electrical requirements, refer to model-specific product page and installation guide on web.

Always consult local and national electric codes.

Minimum 21" clearance for oven door depth when open.

Minimum 23-1/2" deep cutout dimension is critical for proper installation, to ensure that oven’s faceplate will fit flush against cabinet front.

Side filler panels necessary to isolate oven from adjoining cabinets.

Full oven base of solid plywood or similar material required, capable of supporting 200 Lbs. (30" models) or 150 Lbs. (27" models). Install over two runners and flush with toe plate.

Base must be level and cabinet front must be square.

Allow 5" maximum height from oven base to floor, if NO cooktop is installed directly over wall oven.

USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca

Gas Cooktop Installation Over

30"/ 27" Electric Single Wall Oven Specifications

All Frigidaire® Electric Single Wall Ovens are approved to be used beneath any approved Frigidaire® Gas Cooktop. (This installation page excludes approved wall oven model GLEB27Z7H. For model-specific installation details, refer to Gas Cooktop Installation Over 27" Electric Single Wall Oven GLEB27Z7H Specifications pages on web.)

For detailed Gas Cooktop installation, refer to model-specific product page and installation guide on web.

Side filler panel height may need to be modified to accommodate the depth of approved gas cooktop models.

Minimum height opening of 6-1/2" (from top of counter) required in right side filler panel, to route gas and electric hookups.

Allow 4-1/2" maximum height from oven base to floor, if cooktop is installed directly over wall oven.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Specifications subject to change.

GC_EW INST FR 02/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.