To wire through top:

PREPARE THE LOCATION

To wire through top:

.Mark a line distance (A) from the right of the centerline on the underside of the cabinet. Mark the point on this line that is 78” (2.2 cm) from back wall. Drill a 1¼” (3.2 cm) diameter hole (B) through the cab net at this point.

Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x 25.4 cm) Rectangular Vent System

Roof Venting

To make a 4” x 10½” (10.16 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom:

1.Mark lines ½” (1.3 cm) and 4¾” (12.1 cm) from the back wall on the centerline of the underside of cabinet.

.Mark lines 5¼” (13.3 cm) to the right and left of the centerline on the underside of cabinet.

hood

Dim

model

A

 

 

30” & 36”

8³⁄8

models

(21.3 cm)

A

B 78” (2.2

cm)

 

from wall,

 

not cabinet frame

Centerline

 

 

.Use saber or keyhole saw to cut a rectangular opening for vent.

4.Repeat steps 1-3 for the underside of the top of the cabinet.

Centerline Roof Venting

Cabinet cutouts

To wire through wall:

1.Mark a line distance (A) from the right of the centerline on the underside of the wall. Mark the point on this line that is 78” (2.2 cm) from the underside of the cabinet. Drill a 1¼” (3.2 cm) diameter hole (B) through the rear wall at this point.

*1/2 (1.3 cm)

*43/4

5

 

1/4

(12.1 cm)

(13.3 cm)

51/4

 

 

(13.3 cm)

 

 

B

 

 

78

A

(2.2 cm)

 

hood

Dim

model

A

 

 

30” & 36”

8³⁄8

models

(21.3 cm)

 

 

*From wall, not cabinet frame

Wall Venting

To make a 3½” x 10½” (8.9 cm x 26.7 cm) rectangle in the wall:

1.Make 2 lines by measuring 38” (0.9 cm) and 378” (9.8 cm) down from underside of cabinet and mark on the centerline on the back wall.

.Mark lines 5¼” (13.3 cm) to the right and left of the centerline on the wall.

A Centerline

VENTING

Choose venting exhaust discharge from the various options listed - Style 1 - 4 that follows:

Style 1 - Recirculating Hood version

For this installation, go to “Install Range Hood (recirculating version)” on page 11.

.Use saber or keyhole saw to cut a rectangular opening in the wall for the vent.