Frigidaire GL36WC4IES Teflon is a registered trademark of DuPont, Held in place with 2 screws

Models: PL36WC4IEC GL30WC4IEB GL36WC4IES GL30WC4IES GL36WC4IEB PL30WC4IEC

1 8
Download 8 pages 661 b
Page 3
Image 3
Teflon® is a registered trademark of DuPont.

PREPARE THE HOOD

 

PREPARE THE HOOD

3 Remove

Teflon®-coated bottom cover from hood. Set cover and mounting screws aside.

Teflon® is a registered trademark of DuPont.

TEFLON®-COATED BOTTOM COVER

(Held in place with 2 screws)

4

Remove

 

Damper/Duct

 

Connector

 

from inside

 

the hood. Set

 

connector

 

aside - with

 

mounting

 

screws and

 

parts bag.

DAMPER/

DUCT

CONNECTOR

5

Remove

 

either top or

 

back wiring

 

knockout and

 

install

 

approved

Electrical

Cable Clamp.

ELECTRICAL CABLE CLAMP

7

Remove Air

 

Chute - held in

 

place with one

 

(1) screw.

NOTE: Be careful not to disconnect any wires.

8

Remove Baffle

 

from air chute.

AIR CHUTE

(Held in place with 2 screws)

BAFFLEBAFFLE

Non-Ducted Installation - Skip to Step 15.

 

(3) #8 SCREWS
LIGHT
The following

 

PANEL

 

 

Steps (6 thru
(2) #8 SCREWS

 

14) are for

 

 

 

DUCTED

 

 

INSTALLATION

 

 

ONLY.

 

 

6 Remove Light Panel - held in place with (3) #8 screws and Damper/Duct (2) #8 screws. Disconnect light assembly wire harness

(white connector).

9

10 Connector

Rotate baffle. Reinsert baffle into air chute (as shown) so that baffle tabs fit all the way into slots in air chute. An audible “click” will be heard when fully installed. This will close off the air flow through the non-ducted slots on top of hood.

SLOTS

Electrical

Re-install air chute, re-connect wire harness, and replace light panel.

NOTE: Be careful not to trap wires between support fin and light panel.

TABS

SUPPORT FIN

3

Page 3
Image 3
Frigidaire GL36WC4IES Teflon is a registered trademark of DuPont, Held in place with 2 screws, Damper/Duct, Connector