Using Air Conditioner

NOTE: If the air conditioner is turned off, wait 3 minutes before restarting. This allows pressure inside the compressor and equalize. Failure to follow these instructions may be harmful to your unit.

To begin operating the air conditioner, follow these steps:

1.Set the temperature selector to the highest number (coldest or cooler setting).

2.Set the mode control to the highest COOL setting.

3.Adjust the louvers for comfortable air flow (see Air Directional Louvers).

4.Once the room has cooled, adjust the temperature selector to the setting you find most comfortable.

Review the “Air Conditioner Features” section for other settings.

Air Conditioner Features

TEMPERATURE SELECTOR

ma x

7

1

min

cool

 

 

cool

2

3

6

4

5

low fan

low cool

OFF

high cool

high f an

MODE

The controls featured in this manual are representative of many available models.Your model may offer slightly different features.

Cool Mode

The desired cool setting is selected by rotating the MODE knob to the right to the appropriate location.

high cool ” has maximum cooling effect and airflow. “low cool ” has minimum cooling effect and airflow.

Note: If your unit is equipped with a vent handle, keep it closed for maximum efficiency.

Fan Mode

Rotate the MODE knob to the left to select your choice of fan speeds for air circulation. Note: When selecting a fan speed, the compressor will not run.

Temperature Selector

This is used to set the desired room temperature when the unit is being operated in the “COOL MODE”.

To set the desired room temperature, rotate the selector switch to the desired setting. After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature.

Rotate the temperature selector clockwise for higher cool settings. Higher cool settings will provide lower room temperature.

Rotate the temperature selector counter clockwise for lower cool settings. Lower cool settings will provide higher room temperature.

Please always wait 3 minutes when turning unit off then on again, and when changing from cool to fan & back to cool. This prevents compressor from overheating & possible circuit breaker tripping.

 

 

Air Directional Louvers

 

 

 

 

Air directional louvers control air flow direction. Your air conditioner has the louver type

 

 

described below.

 

 

Auger Type

(2-WAY)

AUGER WHEEL

Rotate the Auger Wheels until the desired Left/Right direction is obtained.

5