HCP
4-3
4.4 Turning Slots OFF Press the Menu key on a slot until Slot Off is displayed. Release the key and immediately press
the Temperature key; the choice is locked in.
4.5 Temperature Display Press the Temperature key four times and the temperatures and setpoints will be displayed in this
sequence:
• Top plate temperature
• Bottom plate temperature
• Top plate setpoint
• Bottom plate setpoint 4.6 Temperature Alarms There are five temperature alarms:
• High Temperature
• Low Temperature
• FDA
• Sensor
• Rise Time
If an alarm condition occurs, an audible alarm sounds and the display alternates between the product
selection and the alarm message. Timers cannot be started if a slot is displaying an alarm message.
4.6.1 High and Low-Temperature Alarms
If the slot temperature is above or below the limits for the product selected, the display will
show Slot temp high or slot temp low. An alarm will sound. Press a timer
key to turn off the audible alarm. The audible alarm does not sound during initial cabinet
startup.
4.6.2 Food and Drug Administration (FDA) Alarm
The FDA alarm indicates the slot temperature is below the preset limit to hold a product. An
audible alarm sounds and the alarm message reads Temp Under FDA. Press a timer
key to turn off the audible alarm. The message remains until the slot temperature is within
limits. Press the timer key to clear the FDA alarm.
4.6.3 Sensor-Range Alarm
The Sensor Fail alarm indicates a sensor temperature value above or below the 90-250°F (32-
121°C) range of the slot. An audible alarm sounds. The displayed message is Sens
Alrm. Press a timer key to end the audible alarm. Service is required to correct the sensor
alarm.