3-333.8.2 Troubleshooting the Gas Valve
CONTROLLER
IS CALLING
FOR HEAT.
For non-CE units, verify
gas valve is in ON
position.
Is 24VAC
present across gas
valve main coil?
Is incoming
gas pressure in
accordance with tables in
Section 2.3
of this manual?
Yes
Is outgoing
gas pressure in
accordance with tables on
page 3-7
of this manual?
Yes
Gas valve is OK>
Yes
Probable cause is misadjusted
or failed gas valve. Adjust gas valve in
accordance with Section 3.4 of this
manual. If valve cannot be
adjusted, replace valve.
No
Problem is with
gas supply to fryer.
No
Problem is with 24VAC Circuit.
Refer to "Troubleshooting the
24VAC Circuit" on page 3-30.
No